MétaCan
Menu
Back to cohort
Record W3034949549 · doi:10.1111/pace.13985

The ECG Belt for CRT response trial: Design and clinical protocol

2020· article· en· W3034949549 on OpenAlexaboutno aff
John Rickard, Kevin Jackson, Mauro Biffi, Kevin Vernooy, Alan J. Bank, Jeff Cerkvenik, Subham Ghosh, Michael R. Gold

Bibliographic record

VenuePacing and Clinical Electrophysiology · 2020
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineCardiac resynchronization therapyInvestigational device exemptionVentricleClinical trialClinical endpointRandomized controlled trialCardiologyPhysical medicine and rehabilitationInternal medicineHeart failure

Abstract

fetched live from OpenAlex

The ECG Belt for CRT response trial is designed to test the hypothesis that in patients traditionally less likely to respond to cardiac resynchronization therapy (CRT), an individualized approach utilizing the electrocardiogram (ECG) Belt to guide lead placement, vector selection, and device programming is superior to current standard of care. The ECG Belt is a noninvasive mapping technology designed to measure beat by beat electrical activation of the left ventricle by utilizing unipolar measurements from multiple ECG electrodes on the body surface. The ECG Belt for CRT response trial is a multicenter, prospective, randomized, investigational pre-market research study conducted at 48 centers in the United States, Canada, and Europe and will randomize approximately 400 subjects. The trial has three arms (enrollment will be 2:1:1, respectively): utilization of the Belt to guide implant as well as postimplant programming, utilizing the Belt to guide postimplant programming alone, and a non-Belt control arm. AdaptivCRT will be an option in the treatment arm but not the control arms. The primary endpoint is change in left ventricular end-systolic volume between preimplant and at 6 months. This paper describes the design and analytic plan for the trial.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.014
metaresearch head score (Gemma)0.014
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Protocol · Consensus signal: Protocol
Teacher disagreement score0.059
Threshold uncertainty score0.196

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0140.014
Meta-epidemiology (narrow)0.0050.002
Meta-epidemiology (broad)0.0070.002
Bibliometrics0.0010.003
Science and technology studies0.0020.002
Scholarly communication0.0030.003
Open science0.0020.001
Research integrity0.0050.006
Insufficient payload (model declined to judge)0.0590.013

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.126
GPT teacher head0.464
Teacher spread0.338 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreProtocol

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2020
Admission routes1
Has abstractyes

Explore more

Same venuePacing and Clinical ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207