Moving analytical ultracentrifugation software to a good manufacturing practices (GMP) environment
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
Recent advances in instrumentation have moved analytical ultracentrifugation (AUC) closer to a possible validation in a Good Manufacturing Practices (GMP) environment. In order for AUC to be validated for a GMP environment, stringent requirements need to be satisfied; analysis procedures must be evaluated for consistency and reproducibility, and GMP capable data acquisition software needs to be developed and validated. These requirements extend to multiple regulatory aspects, covering documentation of instrument hardware functionality, data handling and software for data acquisition and data analysis, process control, audit trails and automation. Here we review the requirements for GMP validation of data acquisition software and illustrate software solutions based on UltraScan that address these requirements as far as they relate to the operation and data handling in conjunction with the latest analytical ultracentrifuge, the Optima AUC by Beckman Coulter. The software targets the needs of regulatory agencies, where AUC plays a critical role in the solution-based characterization of biopolymers and macromolecular assemblies. Biopharmaceutical and regulatory agencies rely heavily on this technique for characterizations of pharmaceutical formulations, biosimilars, injectables, nanoparticles, and other soluble therapeutics. Because of its resolving power, AUC is a favorite application, despite the current lack of GMP validation. We believe that recent advances in standards, hardware, and software presented in this work manage to bridge this gap and allow AUC to be routinely used in a GMP environment. AUC has great potential to provide more detailed information, at higher resolution, and with greater confidence than other analytical techniques, and our software satisfies an urgent need for AUC operation in the GMP environment. The software, including documentation, are publicly available for free download from Github. The multi-platform software is licensed by the LGPL v.3 open source license and supports Windows, Mac and Linux platforms. Installation instructions and a mailing list are available from ultrascan.aucsolutions.com.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.