MétaCan
Menu
Back to cohort
Record W3036011354 · doi:10.3389/fcvm.2020.00089

Meta-Analysis Comparing WatchmanTM and Amplatzer Devices for Stroke Prevention in Atrial Fibrillation

2020· review· en· W3036011354 on OpenAlexaboutno aff
Indranill Basu‐Ray, Dibbendhu Khanra, Sumit K. Shah, Sudhanva V. Char, Xiaoming Jia, Wilson Lam, Nilesh Mathuria, Mehdi Razavi, Bhavna Jain, Dhanunjaya Lakkireddy, Saibal Kar, Andrea Natale, Adedayo Adeboye, John L. Jefferies, Sripal Bangalore, Samuel J. Asirvatham, Mohammad Saeed

Bibliographic record

VenueFrontiers in Cardiovascular Medicine · 2020
Typereview
Languageen
FieldMedicine
TopicAtrial Fibrillation Management and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineAtrial fibrillationInternal medicinePericardial effusionCardiologyCardiac tamponadeStroke (engine)EmbolismComplicationTamponadeThrombosisSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: For patients with atrial fibrillation who are at high risk for bleeding or who cannot tolerate oral anticoagulation, left atrial appendage (LAA) closure represents an alternative therapy for reducing risk for thromboembolic events. OBJECTIVES: To compare the efficacy and safety of the Amplatzer and Watchman LAA closure devices. METHODS: A meta-analysis was performed of studies comparing the safety and efficacy outcomes of the two devices. The Newcastle-Ottawa Scale was used to appraise study quality. RESULTS: Six studies encompassing 614 patients were included in the meta-analysis. Overall event rates were low for both devices. No significant differences between the devices were found in safety outcomes (i.e., pericardial effusion, cardiac tamponade, device embolization, air embolism, and vascular complications) or in the rates of all-cause mortality, cardiac death, stroke/transient ischemic attack, or device-related thrombosis. The total bleeding rate was significantly lower in the Watchman group (Log OR= -0.90; 95% CI= -1.76 to -0.04; p=0.04), yet no significant differences was found when the bleeding rate was categorized into major and minor bleeding. Total peridevice leakage rate and insignificant peridevice leakage rate was significantly higher in the Watchman group (Log OR= 1.32; 95% CI= 0.76 to 1.87; p<0.01 and Log OR= 1.11; 95% CI= 0.50 to 1.72; p<0.01 respectively). However, significant peridevice leakages were similar in both the devices. CONCLUSIONS: The LAA closure devices had low complication rates and low event rates. Efficacy and safety were similar between the systems, except for a higher percentage of insignificant peridevice leakages in the Watchman group. A randomized controlled trial comparing both devices is underway which may provide more insight on the safety and efficacy outcomes comparison of the devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.013
metaresearch head score (Gemma)0.023
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.018
Threshold uncertainty score0.067

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0130.023
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0180.060
Bibliometrics0.0050.004
Science and technology studies0.0010.001
Scholarly communication0.0040.002
Open science0.0020.001
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.216
GPT teacher head0.384
Teacher spread0.168 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueFrontiers in Cardiovascular MedicineSame topicAtrial Fibrillation Management and OutcomesFrench-language works237,207