MétaCan
Menu
Back to cohort
Record W3037485509 · doi:10.1089/end.2020.0002

Evaluation of a Single-Use Flexible Cystoscope: A Multi-Institutional International Study

2020· article· en· W3037485509 on OpenAlexaffabout
Kymora B. Scotland, Victor K. Wong, Justin Y.H. Chan, Ehab R. Tawfiek, ALLEN N. CHIURA, Ben H. Chew, Demetrius H. Bagley

Bibliographic record

VenueJournal of Endourology · 2020
Typearticle
Languageen
FieldImmunology and Microbiology
TopicMedical Device Sterilization and Disinfection
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsMedicineSurgeryUrologyMedical physicsInternal medicine

Abstract

fetched live from OpenAlex

Introduction:Acquisition costs and prohibitively expensive technical support for endoscope maintenance, repair, and reprocessing have deterred adoption of flexible cystoscopes by many urologists internationally. This study evaluated the performance of a novel single-use digital cystoscope that can directly connect to a laptop or computer monitor for visualization, obviating the need for a tower. Materials and Methods:The performance characteristics of flexible single-use cystoscopes (NeoScope) were prospectively evaluated vs a reusable flexible cystoscope (Olympus) in three clinical cases and two independent benchtop testing episodes in Canada. Cystoscope maneuverability, imaging, deflection, irrigation, and ease of use of instrumentation were investigated. Additional investigations were performed during clinical use in Zimbabwe (7 patients), Egypt (10 patients), and Dominica (5 patients). Results:Bench testing revealed smaller tip diameter (4.06 vs 6.09 mm) and shorter (35.4 vs 38 cm) single-use cystoscopes vs reusable cystoscopes. Deflection of the single-use scope was superior with an empty working channel (230 up/220 down) vs the reusable (195 up/95 down) but showed a more substantial decrease in deflection on placement of instruments including a grasper. Clinical use revealed satisfactory maneuverability, ease of use of instruments, deflection, and visualization. Conclusions: Benchtop testing performance of the single-use digital flexible cystoscopes was inferior compared with reusable digital cystoscopes. However, these single-use endoscopes offer adequate illumination, imaging, and maneuverability. Direct connection to any computer monitor allowed truly portable use, allowing for treatment of patients in a variety of clinical settings without the need for ancillary equipment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.144
GPT teacher head0.346
Teacher spread0.202 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueJournal of EndourologySame topicMedical Device Sterilization and DisinfectionFrench-language works237,207