MétaCan
Menu
Back to cohort
Record W3039100120 · doi:10.1021/acs.analchem.0c02290

Formation of Gaseous Proteins via the Ion Evaporation Model (IEM) in Electrospray Mass Spectrometry

2020· article· en· W3039100120 on OpenAlexafffund
Elnaz Aliyari, Lars Konermann

Bibliographic record

VenueAnalytical Chemistry · 2020
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsWestern University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsChemistryElectrosprayIonMass spectrometryElectrospray ionizationIon-mobility spectrometryEvaporationAnalytical Chemistry (journal)ElectrostaticsMolecular dynamicsChromatographyChemical physicsComputational chemistryPhysical chemistryOrganic chemistryThermodynamics

Abstract

fetched live from OpenAlex

The mechanisms whereby protein ions are released into the gas phase from charged droplets during electrospray ionization (ESI) continue to be controversial. Several pathways have been proposed. For native ESI the charged residue model (CRM) is favored; it entails the liberation of proteins via solvent evaporation to dryness. Unfolded proteins likely follow the chain ejection model (CEM), which involves the gradual expulsion of stretched-out chains from the droplet. According to the ion evaporation model (IEM) ions undergo electrostatically driven desorption from the droplet surface. The IEM is well supported for small precharged species such as Na+. However, it is unclear whether proteins can show IEM behavior as well. We examined this question using molecular dynamics (MD) simulations, mass spectrometry (MS), and ion mobility spectrometry (IMS) in positive ion mode. Ubiquitin was chosen as the model protein because of its structural stability which allows the protein charge in solution to be controlled via pH adjustment without changing the protein conformation. MD simulations on small ESI droplets (3 nm radius) showed CRM behavior regardless of the protein charge in solution. Surprisingly, many MD runs on larger droplets (5.5 nm radius) culminated in IEM ejection of ubiquitin, as long as the protein carried a sufficiently large positive solution charge. MD simulations predicted that nonspecific salt adducts are less prevalent for IEM-generated protein ions than for CRM products. This prediction was confirmed experimentally. Also, collision cross sections of MD structures were in good agreement with IMS data. Overall, this work reveals that the CRM, CEM, and IEM all represent viable pathways for generating gaseous protein ions during ESI. The IEM is favored for proteins that are tightly folded and highly charged in solution and for droplets in a suitable size regime.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.492
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.253
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations48
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207