MétaCan
Menu
Back to cohort
Record W3040972323 · doi:10.1097/rli.0000000000000702

Evaluation of the Reproducibility of Bolus Transit Quantification With Contrast-Enhanced Ultrasound Across Multiple Scanners and Analysis Software Packages—A Quantitative Imaging Biomarker Alliance Study

2020· article· en· W3040972323 on OpenAlexaff
Michalakis A. Averkiou, Eric K. Juang, Madison K. Gallagher, Maria Alejandra Cuevas, Stephanie R. Wilson, R. Graham Barr, Paul L. Carson

Bibliographic record

VenueInvestigative Radiology · 2020
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsReproducibilityBolus (digestion)UltrasoundScannerNuclear medicineMedicineBiomedical engineeringImaging phantomMean transit timeContrast-enhanced ultrasoundSoftwareRadiologyPerfusionComputer sciencePerfusion scanningMathematicsSurgeryStatisticsArtificial intelligence

Abstract

fetched live from OpenAlex

OBJECTIVES: Contrast enhanced ultrasound (CEUS) is now broadly used clinically for liver lesion detection and characterization. Obstacles to the efforts to quantify perfusion with CEUS have been the lack of a standardized approach and undocumented reproducibility. The use of multiple scanners and different analysis software packages compounds the degree of variability. Our objectives were to standardize a CEUS-based approach for quantification of perfusion-related parameters of liver lesions and to evaluate the variability of bolus transit parameters (rise time [RT], mean transit time [MTT], peak intensity, and area under the curve) obtained from various clinical ultrasound scanners and analysis software. MATERIALS AND METHODS: Bolus transit as a way of evaluating perfusion has been investigated both in vivo and in vitro in the past but without establishing its reproducibility. We developed a tissue flow phantom that produces time-intensity curves very similar to those extracted from clinical cine loops of liver lesions. We evaluated the variability of the bolus transit parameters with 4 commercial scanners (Philips iU22, Philips EPIQ, GE LOGIQ E9, and Siemens Acuson Sequoia) and 3 different analysis software packages in multiple trials (15 per scanner). RESULTS: The variability (coefficient of variation) from repeated trials and while using a single scanner and software was less than 8% for RT, less than 12% for MTT, less than 49% for peak intensity, and less than 50% for area under the curve. Currently, it is not possible to directly compare amplitude values from different scanners and analysis software packages owing to the arbitrary linearization algorithm used among manufacturers; however, it is possible for time parameters (RT and MTT). The variability when using a different scanner with the same analysis software package was less than 9% for RT and less than 21% for MTT. The variability when using a different analysis software with the same scanner was less than 9% for RT and less than 15% for MTT. In all the evaluations we have performed, RT is the least variable parameter, while MTT is only slightly more variable. CONCLUSIONS: The present study will lay the groundwork for multicenter patient evaluations with CEUS quantification of perfusion-related parameters with the bolus transit technique. When using the protocol and method developed here, it is possible to perform perfusion quantification on different scanners and analysis software and be able to compare the results. The current work is the first study that presents a comparison of bolus transit parameters derived from multiple systems and software packages.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.011
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.263
Threshold uncertainty score0.997

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.011
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.003
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.064
GPT teacher head0.332
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueInvestigative RadiologySame topicUltrasound Imaging and ElastographyFrench-language works237,207