MétaCan
Menu
Back to cohort
Record W3041505657 · doi:10.18433/jpps31171

A Sensitive Aptamer-Based Biosensor for Electrochemical Quantification of PSA as a Specific Diagnostic Marker of Prostate Cancer

2020· article· en· W3041505657 on OpenAlexvenueno aff
Shokoufeh Hassani, Armin Salek Maghsoudi, Milad Rezaei Akmal, Soheila Rahmani, Pouria Sarihi, Mohammad Reza Ganjali, Parviz Norouzi, Mohammad Abdollahı

Bibliographic record

VenueJournal of Pharmacy & Pharmaceutical Sciences · 2020
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicAdvanced biosensing and bioanalysis techniques
Canadian institutionsnot available
FundersIran National Science FoundationTehran University of Medical Sciences and Health ServicesNational Science Foundation
KeywordsAptamerAnalyteDetection limitDifferential pulse voltammetryDielectric spectroscopyProstate cancerLinear rangeBiosensorChromatographyProstate-specific antigenColloidal goldElectrochemistryCyclic voltammetryChemistryMaterials scienceElectrodeNanotechnologyNanoparticleCancerMedicineInternal medicineMolecular biology

Abstract

fetched live from OpenAlex

PURPOSE: The current project aimed to design a simple, highly sensitive, and economical label-free electrochemical aptasensor for determination of prostate-specific antigen (PSA), as the gold standard biomarker for prostate cancer diagnosis. The aptasensor was set up using a screen-printed carbon electrode (SPCE) modified by gold nanoparticles (Au NPs) conjugated to thiolated aptamers. METHODS: Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were implemented for electrochemical (EC) characterization of the aptasensor. The determination of PSA was also performed through differential pulse voltammetry (DPV) in [Fe (CN) 6]3-/4- electrolyte solution. RESULTS: The present aptasensor was shown an outstanding linear response in the concentration range of 1 pg/mL - 200 ng/mL with a remarkably lower limit of detection of 0.077 pg/mL. The optimum concentration for PSA separation and the optimum incubation time for antigen-aptamer binding were determined by observing and electing the highest electrochemical responses in a specified time or concentration. CONCLUSION: According to the results of the specificity tests, the designed aptasensor did not show any significant interactions with other analytes in real samples. Clinical functionality of the aptasensor was appraised in serum samples of healthy individuals and patients examining the PSA level through the fabricated aptasensor and the reference methods. Both methods are comparable in sensitivity. The present fabricated PSA aptasensor with substantial characteristics of ultra- sensitivity and cost-effectiveness can be conventionally built and used for the routine check-up of the men for prostate problems.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.022
Threshold uncertainty score0.482

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.052
GPT teacher head0.396
Teacher spread0.343 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations56
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Pharmacy & Pharmaceutical SciencesSame topicAdvanced biosensing and bioanalysis techniquesFrench-language works237,207