MétaCan
Menu
Back to cohort
Record W3042818945 · doi:10.1097/opx.0000000000001535

Validation of a More Reliable Method of Eye Drop Self‐Administration

2020· article· en· W3042818945 on OpenAlexaff
Thomas F. Freddo, Derek Y. Ho, Michelle Steenbakkers, Nadine Furtado

Bibliographic record

VenueOptometry and Vision Science · 2020
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsEye dropMedicineCrossover studyTimololIntraocular pressureOphthalmologySignificant differenceEye irritationAnesthesiaIrritationInternal medicinePlacebo

Abstract

fetched live from OpenAlex

SIGNIFICANCE: We propose an alternative method for eye drop self-administration. Similar IOP reductions were found with this method compared with clinician instillation. The alternative method of self-administration potentially benefits patients who have trouble successfully instilling drops. PURPOSE: The purpose of this study was to validate the efficacy of an alternative method of drop instillation. METHODS: This study is a randomized controlled crossover clinical trial. Thirty participants were recruited. A drop of 0.5% timolol maleate was instilled into subject's eye on two separate visits. On one visit, eye drop instillation was by a trained clinician, and on the other, self-instillation using an alternative method was used. The order was randomly chosen. Intraocular pressure was measured before drop instillation and 2 hours after drop instillation. The investigator was masked during measurement, and an observer recorded the IOP measurements. RESULTS: Mean ± SD IOP measurement before 0.5% timolol maleate instillation measured 13.89 ± 2.29 mmHg. An average reduction 3.75 ± 2.36 mmHg was found with clinician administration, and an average reduction of 3.32 ± 2.31 mmHg was recorded with the new method. No significance was found in IOP reduction between two groups P < .45. Percent reduction was 25.17 ± 16.21% and 24.38 ± 16.31% in clinician instillation and alternative instillation method group, respectively. No significant difference was found. This percentage reduction was similar to previously reported studies. No reported cases of eye infection or irritation were found in any case, within a 3-month follow-up period. CONCLUSIONS: We have proposed a more reliable method for instillation that provides a larger area for instillation and lessen the risk of contamination and patient's fear for eye drops. Similar efficacy was found compared with that of having a clinician directly administer the drop. This alternative method could potentially benefit patients who require topical eye drop therapy and result in increased compliance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.073
Threshold uncertainty score0.172

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.435
Teacher spread0.416 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueOptometry and Vision ScienceSame topicOcular Surface and Contact LensFrench-language works237,207