MétaCan
Menu
Back to cohort
Record W3044548074 · doi:10.1016/j.jmbbm.2020.104002

Stressed volume around vascular canals explains compressive fatigue life variation of secondary osteonal bone but not plexiform bone

2020· article· en· W3044548074 on OpenAlexafffund
Lindsay L. Loundagin, W. Brent Edwards

Bibliographic record

VenueJournal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · 2020
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsAlberta Bone and Joint Health InstituteUniversity of Calgary
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsVolume (thermodynamics)Compression (physics)Materials scienceAnatomyBiomedical engineeringMedicineComposite material

Abstract

fetched live from OpenAlex

The fatigue life of bone illustrates a large degree of scatter that is likely related to underlying differences in composition and microarchitecture. Vascular canals act as stress concentrations, the magnitude and volume of which may depend on the size and spatial distribution of canals. The purpose of this study was to establish the relationship between vascular canal microarchitecture, stressed volume and the fatigue life of both secondary osteonal and plexiform bovine bone. Twenty-one cortical bone samples were prepared from bovine femora and tibiae and imaged using micro-computed tomography (μCT) to quantify canal diameter, canal separation and canal number. Samples were cyclically loaded in zero-compression to a peak magnitude of 95 MPa, and fatigue life was defined as the number of cycles until fracture. Finite element models were created from μCT images and used to quantify the stressed volume, i.e., the volume of bone stressed higher than a yield stress of 108 MPa. Fatigue life ranged from 162-633,437 cycles with the fatigue life of plexiform bone (n = 15) being more than 4.5 times longer than secondary bone (n = 6). The fatigue life of secondary bone was negatively correlated with canal diameter (r2 = 0.73) and canal separation (r2 = 0.56), while the fatigue life of plexiform bone was negatively correlated with canal separation (r2 = 0.41), but positively correlated with canal number (r2 = 0.36). Stressed volume was related to canal microarchitecture in secondary bone only, where canal diameters and canal separation were larger than approximately 50 μm and 200 μm, respectively. Consequently, stressed volume explained 89% of the fatigue life variance in secondary bone but was not related to the fatigue life of plexiform bone. These findings suggest that the volume of the stress concentration surrounding vascular canals is dictated by canal size and spacing and may play an important role in the fatigue failure of osteonal bone. We suspect that a larger stressed volume is more likely to encounter and facilitate the propagation of pre-existing microcracks, thereby leading to a reduction in fatigue life.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.273
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2020
Admission routes2
Has abstractno

Explore more

Same venueJournal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsSame topicOrthopaedic implants and arthroplastyFrench-language works237,207