MétaCan
Menu
Back to cohort

How patient-specific do internal carotid artery inflow rates need to be for computational fluid dynamics of cerebral aneurysms?

2020· article· en· W3046016071 on OpenAlexafffund
Mehdi Najafi, Nicole M Cancelliere, Olivier Brina, Pierre Bouillot, María Isabel Vargas, Bénédicte MA Delattre, Vítor Mendes Pereira, David A. Steinman

Bibliographic record

VenueJournal of NeuroInterventional Surgery · 2020
Typearticle
Languageen
FieldMedicine
TopicIntracranial Aneurysms: Treatment and Complications
Canadian institutionsToronto Western HospitalUniversity of Toronto
FundersSchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen ForschungHeart and Stroke Foundation of Canada
KeywordsInflowInternal carotid arteryMedicineWaveformPulsatile flowComputational fluid dynamicsAneurysmCardiologyHemodynamicsBlood flowInternal medicineSurgeryMechanicsPhysics

Abstract

fetched live from OpenAlex

Background Computational fluid dynamics (CFD) has become a popular tool for studying ‘patient-specific’ blood flow dynamics in cerebral aneurysms; however, rarely are the inflow boundary conditions patient-specific. We aimed to test the impact of widespread reliance on generalized inflow rates. Methods Internal carotid artery (ICA) flow rates were measured via 2D cine phase-contrast MRI for 24 patients scheduled for endovascular therapy of an ICA aneurysm. CFD models were constructed from 3D rotational angiography, and pulsatile inflow rates imposed as measured by MRI or estimated using an average older-adult ICA flow waveform shape scaled by a cycle-average flow rate (Qavg) derived from the patient’s ICA cross-sectional area via an assumed inlet velocity. Results There was good overall qualitative agreement in the magnitudes and spatial distributions of time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and spectral power index (SPI) using generalized versus patient-specific inflows. Sac-averaged quantities showed moderate to good correlations: R2=0.54 (TAWSS), 0.80 (OSI), and 0.68 (SPI). Using patient-specific Qavg to scale the generalized waveform shape resulted in near-perfect agreement for TAWSS, and reduced bias, but not scatter, for SPI. Patient-specific waveform had an impact only on OSI correlations, which improved to R2=0.93. Conclusions Aneurysm CFD demonstrates the ability to stratify cases by nominal hemodynamic ‘risk’ factors when employing an age- and vascular-territory-specific recipe for generalized inflow rates. Qavg has a greater influence than waveform shape, suggesting some improvement could be achieved by including measurement of patient-specific Qavg into aneurysm imaging protocols.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.011
metaresearch head score (Gemma)0.072
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.011
Threshold uncertainty score0.057

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0110.072
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0020.002
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.266
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations27
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueJournal of NeuroInterventional SurgerySame topicIntracranial Aneurysms: Treatment and ComplicationsFrench-language works237,207