Bibliographic record

VenueJournal of Nuclear Engineering and Radiation Science · 2020
Typearticle
Languageen
FieldEngineering
TopicHeat transfer and supercritical fluids
Canadian institutionsPolytechnique Montréal
Fundersnot available
KeywordsSupercritical fluidChokingChoked flowMechanicsSupercritical flowFlow (mathematics)ThermodynamicsMass flowMaterials scienceDischarge coefficientTwo-phase flowMass fluxMass flow rateCritical heat fluxEnvironmental scienceHeat fluxHeat transferNozzlePhysics

Abstract

fetched live from OpenAlex

Abstract The heat transport system of Gen-IV supercritical water-cooled reactors (SCWRs) will operate at pressures close to 25 MPa and outlet temperatures of up to 625 °C. The design and safety analyses of this type of reactors still necessitate among others, experimental information and validation of critical (choked) flows models of water above the thermodynamic critical state. Up to now, choked flow data were collected at atmospheric discharge pressure conditions, without changing the discharge pressure to verify the occurrence of choking flow; in most of the cases, using fluids different from water. This paper presents experimental supercritical water choking flow data collected by using a convergent-divergent test section by changing the discharge pressure to verify the occurrence of choked flow. The critical mass flux is presented as a function of the temperature difference between a pseudo-critical temperature and the bulk fluid temperature. This representation allows us to assess similar experiments performed by using different test sections. Hence, a comparison of actual data with those previously obtained using 1.0 mm and 1.4 mm diameter sharp-edged orifices, shows peculiar differences. The actual experiments were limited by very low values of choking mass flow rates. Furthermore, in some cases, it was observed the presence of an increase in the discharge pressure that seems to indicate the existence of shock-wave structures. We are also able to estimate a pseudo-critical temperature difference below which choking flow systematically occurs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.742
Threshold uncertainty score0.312

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.229
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Nuclear Engineering and Radiation ScienceSame topicHeat transfer and supercritical fluidsFrench-language works237,207