MétaCan
Menu
Back to cohort
Record W3048008493 · doi:10.1002/btm2.10179

A novel bilayered expanded polytetrafluoroethylene glaucoma implant creates a permeable thin capsule independent of aqueous humor exposure

2020· article· en· W3048008493 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueBioengineering & Translational Medicine · 2020
Typearticle
Languageen
FieldMedicine
TopicGlaucoma and retinal disorders
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsPolytetrafluoroethyleneCapsuleAqueous humorGlaucomaMaterials scienceImplantLens capsuleOphthalmologyBiomedical engineeringComposite materialMedicineSurgery

Abstract

fetched live from OpenAlex

Abstract The purpose of these studies was to evaluate clinical, functional, and histopathological features of glaucoma drainage implants (GDIs) fabricated from novel, custom‐tailored expanded polytetrafluoroethylene (ePTFE). Implants of matching footprints were fabricated from silicone (Control) and novel, bilayered ePTFE. ePTFE implants included: (a) one that inflated with aqueous humor (AH) (High), (b) one that inflated with a lower profile (Low), (c) an uninflated implant not connected to the anterior chamber (Flat), and (d) one filled with material that did not allow AH flow (Filled). All implants were placed in adult New Zealand White rabbits and followed over 1–3 months with clinical exams and intraocular pressure. The permeability of tissue capsules surrounding GDIs was assessed using constant‐flow perfusion with fluoresceinated saline at physiologic flow rates. After sacrifice, quantitative histopathological measures of capsule thickness were compared among devices, along with qualitative assessment of cellular infiltration and inflammation. Capsular thickness was significantly reduced in blebs over ePTFE (61.4 ± 53 μm) versus silicone implants (193.6 ± 53 μm, p = .0086). AH exposure did not significantly alter capsular thickness, as there was no significant difference between High and Filled (50.9 ± 29, p = .34) implants. Capsules around ePTFE implants demonstrated permeability with steady‐state pressure: flow relationships at physiologic flow rates and rapid pressure decay with flow cessation, while pressure in control blebs increased even at low flow rates and showed little decay. Perfused fluorescein dye appeared beyond the plate border only in ePTFE implants. ePTFE implants are associated with thinner, more permeable capsules compared to silicone implants simulating presently used devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.850
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.241
Teacher spread0.220 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it