MétaCan
Menu
Back to cohort
Record W3048708260 · doi:10.1097/rli.0000000000000716

Proof of Concept: Phantom Study to Ensure Quality and Safety of Portable Chest Radiography Through Glass During the COVID-19 Pandemic

2020· article· en· W3048708260 on OpenAlexaff
Archana Rai, Kate MacGregor, Bryce Hunt, Alex Gontar, Noah Ditkofsky, Djeven P. Deva, Shobhit Mathur

Bibliographic record

VenueInvestigative Radiology · 2020
Typearticle
Languageen
FieldMedicine
TopicDigital Radiography and Breast Imaging
Canadian institutionsMichener Institute
Fundersnot available
KeywordsRadiographyImaging phantomMedicineNuclear medicineRadiology

Abstract

fetched live from OpenAlex

BACKGROUND: Chest radiography is often used to detect lung involvement in patients with suspected pneumonia. Chest radiography through glass walls of an isolation room is a technique that could be immensely useful in the current COVID-19 pandemic. PURPOSE: The purpose of this study was to ensure quality and radiation safety while acquiring portable chest radiographs through the glass doors of isolation rooms using an adult anthropomorphic thorax phantom. MATERIALS AND METHODS: Sixteen chest radiographs were acquired utilizing different exposure factors without glass, through the smart glass, and through regular glass. Images were scored independently by 2 radiologists for quantum mottle and sharpness of anatomical structures using a 5-point Likert scale. Statistically significant differences in Likert scale scores and entrance surface dose (ESD) between images acquired without glass and through the smart and regular glass were tested. Interreader reliability was also evaluated. RESULTS: Compared with conventional radiography, equal or higher mean image quality scores (mottle and anatomical structures) were observed with the smart glass using 100 kVp at 12 mAs and 20 mAs and 125 kVp at 6.3 mAs (100 kVp at 2 mAs and 125 kVp at 3.2 mAs were used for conventional radiography observations). There was no statistically significant difference in the Likert scale scores for image quality and the entrance surface dose for radiographs acquired without glass, through the smart glass, and through regular glass. Backscatter from the smart glass was minimal at a distance of 3 m and was recorded as zero at a distance of 4 m from the x-ray tube outside an isolation room. CONCLUSIONS: Good-quality portable chest radiographs can be obtained safely through the smart glass doors of the isolation room. However, this technique does result in minor backscatter radiation. Modifications in the exposure factors (such as increasing milliampere seconds) may be required to optimize image quality while using this technique.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.019

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.089
GPT teacher head0.342
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueInvestigative RadiologySame topicDigital Radiography and Breast ImagingFrench-language works237,207