MétaCan
Menu
Back to cohort
Record W3080402515 · doi:10.1109/jsen.2020.3019240

Fabrication of Fast Responsive and Insensitive-Humidity Sensor Based on Polyaniline-WO<sub>3</sub>-CuCl<sub>2</sub> for Hydrogen Sulfide Detection

2020· article· en· W3080402515 on OpenAlexafffund
Najet Belkhamssa, Mohamed Ksibi, Andy Shih, Ricardo Izquierdo

Bibliographic record

VenueIEEE Sensors Journal · 2020
Typearticle
Languageen
FieldEngineering
TopicGas Sensing Nanomaterials and Sensors
Canadian institutionsÉcole de Technologie Supérieure
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsPolyanilineMaterials scienceTungsten trioxideDetection limitCopper chlorideTungstenGrapheneChlorideInorganic chemistryChemical engineeringCopperAnalytical Chemistry (journal)Nuclear chemistryPolymer chemistryNanotechnologyComposite materialChemistryPolymerOrganic chemistryMetallurgyChromatography

Abstract

fetched live from OpenAlex

Simple and low-cost hydrogen sulfide gas sensors based on polyaniline-copper chloride and polyaniline- tungsten trioxide- copper chloride composites were developed. The sensing film was produced by drop cast of the dispersed composite on top of screen-printed carbon electrodes on a flexible polyethylene terephthalate substrate. A fast onset time of detection of 10 s and 20 s towards 0.1 ppm of hydrogen sulfide were obtained for polyaniline-tungsten trioxide-copper chloride and polyaniline-copper chloride sensors, respectively. The calibration curve displays a good working range between 0.1 and 1 ppm with a limit of detection and limit of quantification of 155 and 512 ppb, respectively. The polyaniline-CuCl <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> sensor presented a high response to humidity change. In contrast, the incorporation of tungsten oxide into the polyaniline-CuCl <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> composite exhibited significantly improved the response time to target gas from 15 min to 4 min and make it nearly insensitive to humidity changes up to 40 %. Gas-sensing tests show that polyaniline- tungsten trioxide-copper chloride composites exhibit a high and fast response as well as an excellent selectivity to hydrogen sulfide at ppm level in room temperature. The proposed sensors could be used for different industrial applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.084
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.207
Teacher spread0.193 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Sensors JournalSame topicGas Sensing Nanomaterials and SensorsFrench-language works237,207