MétaCan
Menu
← Back to cohort
Record W3081678213 · doi:10.1111/cid.12941

Impact of fully or partially guided surgery on the position of single implants immediately placed in maxillary incisor sockets: A randomized controlled clinical trial

2020· article· en· W3081678213 on OpenAlexvenueno aff
Bruno Kraft, Fausto Frizzera, Rubens Moreno de Freitas, Guilherme José Lopes Pimentel de Oliveira, Élcio Marcantônio

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2020
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineImplantMaxillary lateral incisorMaxillary incisorIncisorResonance frequency analysisOrthodonticsDentistryPosition (finance)Randomized controlled trialMaxillary central incisorSurgeryDental implant

Abstract

fetched live from OpenAlex

PURPOSE: The aim of this study was to compare the deviation of the implant position after placement in single maxillary incisor post-extraction sockets between fully and partially guided surgery. MATERIALS AND METHODS: Twenty-four patients with a failing maxillary incisor were randomly allocated into two groups: the partially guided surgery (PGS, n = 12) group or fully guided surgery (FGS, n = 12) group. Clinical analyses, intra-oral scans, and computed tomography scans (CT) were initially performed to define the virtual positioning of the implants and fabrication of the 3D printed surgical guides. A narrow, 3.5 × 16 mm implant was placed in each socket. In this moment, the insertion torque (IT) was assessed and resonance frequency analysis (RFA) was performed. All patients received an immediate provisional without occlusal contacts. Another CT scan was performed after the procedures to compare the implant position with the virtually planned position. RESULTS: Significant deviations occurred at the implant apex, according to the global and facial-palatal analyses, in comparison to its cervical position. The PGS group also presented a larger deviation in the MD position. No statistical differences between the groups were detected, however, there was a tendency of lower angular deviation in the PGS group. CONCLUSIONS: While there was a slight deviation from the virtually planned position of the implant to the actual position and a tendency of lower angular deviation in the PGS group, there was no difference among groups regarding its position and primary stability. (UNT: 1111-1214-2812 - http://www.ensaiosclinicos.gov.br/rg/RBR-4tmcrk/).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0040.002
Bibliometrics0.0010.001
Science and technology studies0.0000.002
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0050.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.327
GPT teacher head0.510
Teacher spread0.183 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→