MétaCan
Menu
Back to cohort
Record W3084420583 · doi:10.1093/ons/opaa271

Considering Pedicle Screw Resistance in Electromyography of the Spine

2020· article· en· W3084420583 on OpenAlexaffabout
Jonathan Norton, Michael Kindrachuk, Daryl R. Fourney

Bibliographic record

VenueOperative Neurosurgery · 2020
Typearticle
Languageen
FieldMedicine
TopicIntraoperative Neuromonitoring and Anesthetic Effects
Canadian institutionsRoyal University Hospital
Fundersnot available
KeywordsMedicineElectromyographyBiomedical engineeringOrthodonticsPhysical medicine and rehabilitation

Abstract

fetched live from OpenAlex

BACKGROUND: Evoked electromyographic (EMG) monitoring of pedicle screws has been shown to be an effective adjuvant to image guidance or direct visualization of pedicle screw placement. Electrical stimulation is delivered to the head of the screw at various intensities until a muscle potential is evoked. This practice is based on the fact that an intact pedicle effectively shields nerve roots from electrical stimulus. Several factors have been debated that may affect the interpretation of results; however, to the best of our knowledge, the electrical resistance of modern manufactured pedicle screws and stimulation devices has not been studied. OBJECTIVE: To determine if pedicle screw resistances affect triggered EMG. METHODS: Samples of the most commonly implanted pedicle screws in Canada were obtained, with diameters ranging from 4.5 to 7 mm. The resistance between the screw head and thread and core at the midpoint and tip of the screw was recorded using a Multimeter in accordance with IEEE standards. For screws with variable threads, the midpoint was considered the point at which the thread pitch changed. RESULTS: All screws had low impedances when tested at the point of the screw, but much higher when the cup is tested. The resistance of different manufactures' screws was significantly different, ranging from 0.514 to 2156 Ohms. CONCLUSION: Despite differences in resistance, most screws had resistances in ranges that allow for triggered EMG pedicle integrity testing. Resistance from pedicle screws is an important consideration in EMG monitoring of the spine.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.006
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.270
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueOperative NeurosurgerySame topicIntraoperative Neuromonitoring and Anesthetic EffectsFrench-language works237,207