MétaCan
Menu
Back to cohort
Record W3087878754 · doi:10.23967/dbmc.2020.056

Effect of Selected Moisture Reference Year on the Durability Assessment of Wall Assemblies under Future Climates

2020· article· en· W3087878754 on OpenAlexaffabout
Sahar Sahyoun, Hua Ge, Chetan Aggarwal, Maurice Defo, Terrence J. Moore

Bibliographic record

VenueXV International Conference on Durability of Building Materials and Components. eBook of Proceedings · 2020
Typearticle
Languageen
FieldEngineering
TopicHygrothermal properties of building materials
Canadian institutionsNational Research Council CanadaConcordia University
Fundersnot available
KeywordsMoistureRanking (information retrieval)Environmental scienceDurabilitySelection (genetic algorithm)ASHRAE 90.1Index (typography)MeteorologyComputer scienceGeographyDatabaseInformation retrievalMachine learning

Abstract

fetched live from OpenAlex

Hygrothermal simulations are commonly used to evaluate the moisture damage risk of building envelopes over the long-term. For such assessment to be accurate, a proper selection of representative climate data is required. A common method is the selection of a moisture reference year from a set of available long-term climate data. For instance, the IRC-led research consortium MEWS (Moisture Management of Exterior Wall Systems) developped the Moisture Index (MI) approach, which consists of a wetting and a drying function. Therefore, the reference year selection would be based on the MI ranking. ASHRAE 160 is adopting a procedure named “the severity index” for the selection of moisture reference year. Combining climate loads and durability criteria, this method allows to select more “severe” weather years, thus providing a more representative ranking of the weather data. The objective of this paper is two-fold. First, to compare the selection of the moisture reference year based on two different approaches for both historical and future climate loads. Second, the effect of chosen representative years is evaluated and compared to long-term simulation periods (of 31-years) based on the durability of building assemblies. The methodology includes hygrothermal simulations of two different types of wall assemblies located in three different Canadian cities under a changing climate. In general, higher mold index values were obtained by the long-term simulation and MRYs using Isev. Comparing the results of different models under future climates, the three methods were in good agreement, except for a brick wall facing WDR in Ottawa and Vancouver. This might be due to the Isev correlations were developed based on a north-facing stucco wall. In addition, for a north-facing wall, an extremely low mold index was predicted for Vancouver, compared to WDR direction. Thus, considering a north-facing wall as a criterion for performance evaluation might misrepresent the reality in some locations. Hence, both WDR and North orientations should be considered. A further study will be carried out to investigate the performance evaluation of Isev method for different types of wall systems and orientations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.027
Threshold uncertainty score0.866

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.267
Teacher spread0.235 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueXV International Conference on Durability of Building Materials and Components. eBook of ProceedingsSame topicHygrothermal properties of building materialsFrench-language works237,207