MétaCan
Menu
Back to cohort
Record W3088959492 · doi:10.1097/opx.0000000000001561

Objective and Subjective Evaluation of Clinical Performance of Scleral Lens with Varying Limbal Clearance in Keratoconus

2020· article· en· W3088959492 on OpenAlexaff
Debby Yeung, Paul J. Murphy, Luigina Sorbara

Bibliographic record

VenueOptometry and Vision Science · 2020
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsKeratoconusScleral lensOphthalmologyMedicineOptometryCornea

Abstract

fetched live from OpenAlex

SIGNIFICANCE: This study evaluates how limbal clearance (LC) may impact the clinical performance of scleral lenses based on subjective response on comfort and ocular responses. Limbal zone designs in scleral lenses might affect the integrity of the limbal epithelial tissue as a result of a combined hypoxic and compression-related etiology. PURPOSE: This study aimed to investigate the clinical performance and ocular and subjective responses to the wear of scleral lenses having varying LC. METHODS: Lenses with varying LC with a difference of 50 μm were fitted on and compared among keratoconic participants. The lenses were worn during a 2-week period. Visual analog scales concerning subjective comfort were completed. Ocular surface findings including hyperemia, limbal staining, and corneal swelling were compared. RESULTS: Participants reported greater comfort achieved with high LC. No difference in limbal and bulbar hyperemia was found (P > .05). Corneal response to scleral lens wear with both low and high LCs seems to result in similar perilimbal staining and negative corneal staining. An increase in corneal pachymetric values was noted at the central and peripheral cornea, with no difference between low- and high-LC lenses (all, P < .05). Quadrant-specific analysis indicated that all meridians at both 6 and 8 mm were increased for the low-LC lenses (all, P < .05) and only the temporal region for the high-LC lenses (P = .02). CONCLUSIONS: Limbal clearance may play an important role in subjective performance in scleral lenses but does not impact the degree of hyperemia in either the limbal or bulbar region. Although low LC might result in more compression-related changes to ocular surface, high LC is associated with greater comfort and greater edematous changes. Limbal zone designs in scleral lenses might affect the integrity of the limbal epithelial tissue as a result of a combined hypoxic and compression-related etiology.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.052
Threshold uncertainty score0.214

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.056
GPT teacher head0.449
Teacher spread0.393 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueOptometry and Vision ScienceSame topicOcular Surface and Contact LensFrench-language works237,207