MétaCan
Menu
Back to cohort
Record W3093675825 · doi:10.1080/00295450.2020.1794436

A Radiation-Tolerant Wireless Communication System for Severe Accident Monitoring Without Relying on Rad-Hardened Electronic Components

2020· article· en· W3093675825 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueNuclear Technology · 2020
Typearticle
Languageen
FieldEngineering
TopicRadiation Effects in Electronics
Canadian institutionsWestern University
Fundersnot available
KeywordsDose rateNuclear power plantComputer scienceNuclear powerWirelessElectronic systemsRadiation monitoringAccident (philosophy)RadiationReliability engineeringEngineeringTelecommunicationsMedical physicsElectronic engineeringPhysics

Abstract

fetched live from OpenAlex

One of the most important considerations in the design of electronic systems for post-accident monitoring in a nuclear power plant is how to deal with the complex and uncertain radiation environments. Without using special design methodologies and adequate protection, nonradiation-hardened commercial-off-the-shelf (COTS) electronic components can easily be damaged. In this paper, a new design methodology is proposed so that COTS components can be used in building post-accident monitoring systems (PAMSs). To validate the effectiveness of the methodology, a prototype wireless post-accident monitoring system has been designed, implemented, and evaluated in a 60Co gamma radiation environment. It has been concluded that even at a dose rate of 20 krad (Si)/h, the prototype system operates satisfactorily even after being irradiated for 21 h. The system also operates satisfactorily at a low dose rate of 200 rad (Si)/h. It can be concluded that, even with COTS components, the proposed design can effectively extend the lifespan of post-accident monitoring systems in different radiation environments. Based on the experimental results, it can be said with confidence that the developed radiation-tolerant wireless monitoring system can operate for at least 8 h under the highest observed dose rate (530 Sv/h) encountered during the Fukushima Daiichi nuclear disaster and would have been able to provide crucial information to first responders following the accident.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.187
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.221
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it