MétaCan
Menu
Back to cohort
Record W3094581945 · doi:10.1002/mrm.28552

Quantitative and simultaneous measurement of oxygen consumption rates in rat brain and skeletal muscle using <sup>17</sup>O MRS imaging at 16.4T

2020· article· en· W3094581945 on OpenAlexaff
Hannes Wiesner, Dávid Z. Balla, Klaus Scheffler, Kǎmil Uǧurbil, Xiaohong Zhu, Wei Chen, Kâmil Uludaǧ, R Pohmann

Bibliographic record

VenueMagnetic Resonance in Medicine · 2020
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity Health Network
FundersNational Institute of Biomedical Imaging and BioengineeringNational Institutes of HealthNational Cancer InstituteNational Institute of Neurological Disorders and StrokeNational Institute of Mental HealthInstitute for Basic ScienceMax-Planck-Gesellschaft
KeywordsOxygenSkeletal muscleMetabolic rateChemistryWashoutVentilation (architecture)MetabolismApparent oxygen utilisationRespirationInternal medicineAnatomyBiochemistryMedicine

Abstract

fetched live from OpenAlex

Purpose Oxygen‐17 (17O) MRS imaging, successfully used in the brain, is extended by imaging the oxygen metabolic rate in the resting skeletal muscle and used to determine the total whole‐body oxygen metabolic rate in the rat. Methods During and after inhalations of 17O2 gas, dynamic 17O MRSI was performed in rats (n = 8) ventilated with N2O or N2 at 16.4 T. Time courses of the H217O concentration from regions of interest located in brain and muscle tissue were examined and used to fit an animal‐adapted 3‐phase metabolic model of oxygen consumption. CBF was determined with an independent washout method. Finally, body oxygen metabolic rate was calculated using a global steady‐state approach. Results Cerebral metabolic rate of oxygen consumption was 1.97 ± 0.19 μmol/g/min on average. The resting metabolic rate of oxygen consumption in skeletal muscle was 0.32 ± 0.12 μmol/g/min and >6 times lower than cerebral metabolic rate of oxygen consumption. Global oxygen consumed by the body was 24.2 ± 3.6 mL O2/kg body weight/min. CBF was estimated to be 0.28 ± 0.02 mL/g/min and 0.34 ± 0.06 mL/g/min for the N2 and N2O ventilation condition, respectively. Conclusion We have evaluated the feasibility of 17O MRSI for imaging and quantifying the oxygen consumption rate in low metabolizing organs such as the skeletal muscle at rest. Additionally, we have shown that CBF is slightly increased in the case of ventilation with N2O. We expect this study to be beneficial to the application of 17O MRSI to a wider range of organs, although further validation is advised.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.049
GPT teacher head0.337
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207