MétaCan
Menu
Back to cohort
Record W3095424287 · doi:10.1177/0846537120968919

Radiological Society of North America (RSNA) Expert Consensus Statement Related to Chest CT Findings in COVID-19 Versus CO-RADS: Comparison of Reporting System Performance Among Chest Radiologists and End-User Preference

2020· article· en· W3095424287 on OpenAlexaff
Siobhan B. O’ Neill, Danielle Byrne, Néstor L. Müller, Sabeena Jalal, William Parker, Savvas Nicolaou, Ana-Maria Bilawich

Bibliographic record

VenueCanadian Association of Radiologists Journal · 2020
Typearticle
Languageen
FieldMedicine
TopicRadiology practices and education
Canadian institutionsVancouver General HospitalUniversity of British Columbia
Fundersnot available
KeywordsMedicineCoronavirus disease 2019 (COVID-19)Radiological weaponRadiologyStatement (logic)2019-20 coronavirus outbreakMedical physicsInternal medicinePathology

Abstract

fetched live from OpenAlex

Purpose: The RSNA expert consensus statement and CO-RADS reporting system assist radiologists in describing lung imaging findings in a standardized manner in patients under investigation for COVID-19 pneumonia and provide clarity in communication with other healthcare providers. We aim to compare diagnostic performance and inter-/intra-observer among chest radiologists in the interpretation of RSNA and CO-RADS reporting systems and assess clinician preference. Methods: Chest CT scans of 279 patients with suspected COVID-19 who underwent RT-PCR testing were retrospectively and independently examined by 3 chest radiologists who assigned interpretation according to the RSNA and CO-RADS reporting systems. Inter-/intra-observer analysis was performed. Diagnostic accuracy of both reporting systems was calculated. 60 clinicians participated in a survey to assess end-user preference of the reporting systems. Results: Both systems demonstrated almost perfect inter-observer agreement (Fleiss kappa 0.871, P < 0.0001 for RSNA; 0.876, P < 0.0001 for CO-RADS impressions). Intra-observer agreement between the 2 scoring systems using the equivalent categories was almost perfect (Fleiss kappa 0.90-0.92, P < 0.001). Positive predictive values were high, 0.798-0.818 for RSNA and 0.891-0.903 CO-RADS. Negative predictive value were similar, 0.573-0.585 for RSNA and 0.573-0.58 for CO-RADS. Specificity differed between the 2 systems, 68-73% for CO-RADS and 52-58% for RSNA with superior specificity of CO-RADS. Of 60 survey participants, the majority preferred the RSNA reporting system rather than CO-RADS for all options provided (66.7-76.7%; P < 0.05). Conclusions: RSNA and CO-RADS reporting systems are consistent and reproducible with near perfect inter-/intra-observer agreement and excellent positive predictive value. End-users preferred the reporting language in the RSNA system.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.063
metaresearch head score (Gemma)0.140
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: Reporting · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Commentary · Consensus signal: none
Teacher disagreement score0.937
Threshold uncertainty score0.334

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0630.140
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.002
Science and technology studies0.0010.001
Scholarly communication0.0020.001
Open science0.0010.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.106
GPT teacher head0.360
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designNot applicable
DomainReporting
GenreCommentary

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueCanadian Association of Radiologists JournalSame topicRadiology practices and educationFrench-language works237,207