MétaCan
Menu
Back to cohort
Record W3096049656 · doi:10.2967/jnumed.120.254656

Feasibility of single-time-point dosimetry for radiopharmaceutical therapies

2020· article· en· W3096049656 on OpenAlexafffund
Xinchi Hou, Julia Brosch-Lenz, Carlos Uribe, Alessandro Desy, Guido Böning, Jean‐Mathieu Beauregard, A. Ćeller, Arman Rahmim

Bibliographic record

VenueJournal of Nuclear Medicine · 2020
Typearticle
Languageen
FieldMedicine
TopicRadiopharmaceutical Chemistry and Applications
Canadian institutionsUniversity of British ColumbiaUniversité LavalUniversity of British Columbia Hospital
FundersCanadian Institutes of Health Research
KeywordsDosimetryRadionuclide therapyNuclear medicineMedicinePopulationMedical physics

Abstract

fetched live from OpenAlex

Because of challenges in performing routine personalized dosimetry in radiopharmaceutical therapies, interest in single-time-point (STP) dosimetry, particularly using only a single SPECT scan, is on the rise. Meanwhile, there are questions about the reliability of STP dosimetry, with limited independent validations. In the present work, we analyzed 2 STP dosimetry methods and evaluated dose errors for several radiopharmaceuticals based on effective half-life distributions. <b>Methods:</b> We first challenged the common assumption that radiopharmaceutical effective half-lives across the population are gaussian-distributed (i.e., follow a normal distribution). Then, dose accuracy was estimated using 2 STP dosimetry methods for a wide range of potential post injection (p.i.) scan time points for different radiopharmaceuticals applied to neuroendocrine tumors and prostate cancer. The accuracy and limitations of each of the STP methods were discussed. <b>Results:</b> A lognormal distribution was more appropriate for capturing effective half-life distributions. The STP framework was promising for dosimetry of <sup>177</sup>Lu-DOTATATE and for kidney dosimetry of different radiopharmaceuticals (errors &lt; 30%). Meanwhile, for some radiopharmaceuticals, STP accuracy was compromised (e.g., in bone marrow and tumors for <sup>177</sup>-labeled prostate-specific membrane antigen [PSMA])). The optimal SPECT scanning time for <sup>177</sup>Lu-DOTATATE was approximately 72 h p.i., whereas 48&nbsp;h p.i. was better for <sup>177</sup>Lu-PSMA. <b>Conclusion:</b> Simplified STP dosimetry methods may compromise the accuracy of dose estimates, with some exceptions, such as for <sup>177</sup>Lu-DOTATATE and for kidney dosimetry in different radiopharmaceuticals. Simplified personalized dosimetry in the clinic continues to be challenging. On the basis of our results, we make suggestions and recommendations for improved personalized dosimetry using simplified imaging schemes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.387
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.127
GPT teacher head0.381
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations77
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Nuclear MedicineSame topicRadiopharmaceutical Chemistry and ApplicationsFrench-language works237,207