MétaCan
Menu
Back to cohort
Record W3096694932 · doi:10.1183/23120541.00435-2020

Controlled<i>versus</i>free breathing for multiple breath nitrogen washout in healthy adults

2020· article· en· W3096694932 on OpenAlexafffund
Blake M. Handley, Edward Jeagal, R E Schoeffel, Tanya Badal, David G. Chapman, Catherine Farrow, Gregory G. King, Paul D. Robinson, Stephen Milne, Cindy Thamrin

Bibliographic record

VenueERJ Open Research · 2020
Typearticle
Languageen
FieldMedicine
TopicChronic Obstructive Pulmonary Disease (COPD) Research
Canadian institutionsSt. Paul's HospitalUniversity of British Columbia
FundersMitacs
KeywordsMedicineVentilation (architecture)Nitrogen washoutRepeatabilityBreathingFunctional residual capacityTidal volumeWashoutRespiratory minute volumeRespiratory systemInternal medicineCardiologyAnesthesiaLung volumesStatisticsLungMathematics

Abstract

fetched live from OpenAlex

Multiple breath nitrogen washout (MBNW) quantifies ventilation heterogeneity. Two distinct protocols are currently used for MBNW testing: “controlled breathing”, with targeted tidal volume (VT) and respiratory rate (RR); and “free breathing”, with no constraints on breathing pattern. Indices derived from the two protocols (functional residual capacity (FRC), lung clearance index (LCI),Scond,Sacin) have not been directly compared in adults. We aimed to determine whether MBNW indices are comparable between protocols, to identify factors underlying any between-protocol differences and to determine the between-session variabilities of each protocol. We performed MBNW testing by both protocols in 27 healthy adult volunteers, applying the currently proposed correction forVTtoScondandSacinderived from free breathing. To establish between-session variability, we repeated testing in 15 volunteers within 3 months. While FRC was comparable between controlledversusfree breathing 2.92 (0.86)versus2.94 (0.89) L, p=0.75), indices of ventilation heterogeneity derived from the two protocols were not, with poor correlation forScond(r=0.18, p=0.36) and significant bias forSacin(0.057 (0.021) L−1versus0.085 (0.038) L−1, p=0.0004). Between-protocol differences inSacinwere related to differences in the breathing pattern,i.e. VT(p=0.004) and RR (p=0.01), rather than FRC. FRC and LCI showed good between-session repeatability, butScondandSacinfrom free breathing showed poor repeatability with wide limits of agreement. These findings have implications for the ongoing clinical implementation of MBNW, as they demonstrate thatScondandSacinfrom free breathing, despiteVTcorrection, are not equivalent to the controlled breathing protocol. The poor between-session repeatability ofScondduring free breathing may limit its clinical utility.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.121
GPT teacher head0.420
Teacher spread0.299 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueERJ Open ResearchSame topicChronic Obstructive Pulmonary Disease (COPD) ResearchFrench-language works237,207