MétaCan
Menu
Back to cohort
Record W3097712954 · doi:10.1097/cce.0000000000000234

Video Laryngoscope Intubation With an Aerosol Barrier Device: A Randomized Sequential Crossover Pilot Study

2020· article· en· W3097712954 on OpenAlexaff
Masafumi Idei, Takeshi Nomura, Philippe Jouvet, Carl Eric Aubin, Atsushi Kawaguchi, Masashi Nakagawa

Bibliographic record

VenueCritical Care Explorations · 2020
Typearticle
Languageen
FieldMedicine
TopicInfection Control and Ventilation
Canadian institutionsChildren's Hospital of Eastern OntarioUniversité de MontréalPolytechnique MontréalCentre Hospitalier Universitaire Sainte-Justine
FundersTokyo Women's Medical University
KeywordsInterquartile rangeIntubationMedicineAnesthesiaCrossover studyEndotracheal intubationAirwayRandomized controlled trialAirway managementEndotracheal tubeVisual analogue scaleVideo laryngoscopeEmergency medicineTracheal intubationSurgery

Abstract

fetched live from OpenAlex

Objectives: To assess the impact of the use of aerosol barrier device, Splashguard-CG, on the endotracheal intubation with different types of laryngoscope. Design: A pilot randomized sequential crossover simulation study. Setting: A single academic center in Japan. Subjects: Physicians in a single academic university hospital in Japan. Interventions: Use of Splashguard-CG. Measurements and Main Results: All participants were asked to perform endotracheal intubation to a manikin simulator using three different devices (Macintosh laryngoscope; Airway Scope [Nihon Kohden, Tokyo, Japan]; and McGRATH MAC [Aircraft Medical, Edinburgh, United Kingdom]) with and without Splashguard-CG in place, which required a total of six attempts and measured the intubation time as the primary outcome. Thirty physicians (15 experienced physicians and 15 less-experienced physicians) were included. Intubation time using Macintosh laryngoscope was significantly longer in the group with Macintosh laryngoscope and Splashguard-CG compared with the group without Splashguard-CG by the median difference of 4.3 seconds (interquartile range, 2.6–7.4 s; p < 0.001). There was no significant increase in the intubation time with or without Splashguard-CG for the Airway Scope (0.6 s; interquartile range, –3.7 to 3.2 s; p = 0.97) and the McGRATH MAC (0.5 s; interquartile range, –1.4 to 4.6 s; p = 0.09). This trend was found in both the experienced and less-experienced groups. We observed significant increases of subjective difficulty of the endotracheal intubation evaluated by using a Visual Analog Scale in the Splashguard-CG groups for all three types of devices. Conclusions: The use of a video laryngoscope with an aerosol barrier device does not impact the time required endotracheal intubation in a simulation environment. This method can be considered as airway management for coronavirus disease 2019.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.279
Threshold uncertainty score0.815

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.071
GPT teacher head0.355
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueCritical Care ExplorationsSame topicInfection Control and VentilationFrench-language works237,207