MétaCan
Menu
Back to cohort

Extracorporeal membrane oxygenation (ECMO) in patients with severe COVID-19 adult respiratory distress syndrome: a systematic review and meta-analysis

2020· review· en· W3100852046 on OpenAlexaboutno aff
Hany Elsayed, Aly Sherif Hassaballa, Taha Ahmed, Mohammed Gumaa, Hazem Youssef Sharkawy

Bibliographic record

Venuenot available
Typereview
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineARDSMeta-analysisExtracorporeal membrane oxygenationConfidence intervalCochrane LibrarySubgroup analysisMechanical ventilationRespiratory distressMEDLINECoronavirus disease 2019 (COVID-19)Internal medicineAnesthesiaLungInfectious disease (medical specialty)Disease

Abstract

fetched live from OpenAlex

Background COVID 19 is the most recent cause of Adult respiratory distress syndrome ARDS. Extracorporeal membrane oxygenation (ECMO) can support gas exchange in patients failing conventional mechanical ventilation, but its role is still controversial. We conducted a systematic review and meta-analysis on ECMO for COVID-associated ARDS to study its outcome. Materials and Methods CENTRAL, MEDLINE/PubMed, Cochrane Library, and Scopus were systematically searched from inception to May 28, 2020. Studies reporting five or more patients with COVID 19 infection treated venovenous with ECMO were included. The main outcome assessed was mortality. Baseline, procedural, outcome, and validity data were systematically appraised and pooled with random-effect methods. The validity of all the included observational studies was appraised with the Newcastle Ottawa scale. Meta-regression and publication bias were tested. This trial was registered with PROSPERO under registration number CRD42020183861 Results From 1647 initial citations, 34 full text articles were analysed and 12 studies were selected, including 194 patients with confirmed COVID 19 infection requiring ICU admission and venovenous ECMO treatment. Random-effect pooled estimates suggested an overall in-hospital mortality risk ratio of 0.49 (95% confidence interval 0.259 to 0.721; I2 = 94%). Subgroup analysis according to country of origin showed persistent heterogeneity only in the 7 Chinese studies with pooled estimate mortality risk ratio of 0.66 (I2 = 87%) (95% CI = 0.39-0.93), while the later larger studies coming from the USA showed pooled estimate mortality risk ratio of 0.41 (95% CI 0.28-0.53) with homogeneity (p=0.67) similar to France with a pooled mortality risk ratio of 0.26 (95% CI 0.08-0.43) with homogeneity (p=0.86).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.012
metaresearch head score (Gemma)0.024
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.020
Threshold uncertainty score0.061

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0120.024
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0200.036
Bibliometrics0.0080.008
Science and technology studies0.0010.001
Scholarly communication0.0030.002
Open science0.0020.002
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.280
Teacher spread0.234 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2020
Admission routes1
Has abstractyes

Explore more

Same topicMechanical Circulatory Support DevicesFrench-language works237,207