<i>In Vitro</i> Measurements of Spiriva Respimat Dose Delivery in Mechanically Ventilated Tracheostomy Patients

2020· article· en· W3104090063 on OpenAlexaff
Rym Mehri, Abubakar Alatrash, Nicholas Ogrodnik, Edgar Matida, Frank Fiorenza

Bibliographic record

VenueJournal of Aerosol Medicine and Pulmonary Drug Delivery · 2020
Typearticle
Languageen
FieldMedicine
TopicInhalation and Respiratory Drug Delivery
Canadian institutionsUniversity of OttawaCarleton University
Fundersnot available
KeywordsMechanical ventilationMedicineMechanical ventilatorAdapter (computing)MistAnesthesiaBiomedical engineeringComputer science

Abstract

fetched live from OpenAlex

Background: For patients with severe chronic obstructive pulmonary disease under invasive mechanical ventilation, medication for aerosol therapy is delivered through tracheostomy or endotracheal airways. Typically, these medications (such as bronchodilators) are long-acting formulations that are delivered through Soft Mist ™ Inhalers (SMI), or Pressurized Metered-Dose Inhalers. The Respimat ® SMI has been shown to have increased efficiency because of its slow and prolonged aerosol mist and has gained popularity in clinical settings. However, the Respimat was not designed for drug delivery through artificial airways. Therefore, there is a need for SMI adapters in intensive care for use in mechanical ventilator circuits. The purpose of this study was to evaluate the performance of a new Respimat adapter (ODAPT ™ for mechanical ventilator [ODAPT MV]) for use in mechanical ventilator circuits which, in combination with a Pulmodyne T-piece adapter, allows use without interruption of the circuit in case of medication replacement. Methods: Tiotropium delivery to the lungs, using Respimat, was assessed using the ODAPT MV adapter within an in vitro setup, including a three-dimensional printed trachea model and a mechanical ventilator. Medication deposition and losses were investigated using two commonly used tracheostomy tube (TT) sizes (6 and 8 mm inner canula) for two flow rates (45 and 60 L/min) under different conditions (30%–50%. and 100% relative humidity [RH]). Medication delivery using the ODAPT MV adapter was compared with the RTC-26C in-line adapter under similar conditions (8 mm TT size, 100% RH at 45 L/min). Results: It was found that 7.1%–13.4% of the nominal dose (ND) was lost in the ODAPT MV adapter for different TT size, RH, and flow rates used. Higher losses were found in the inhaler's mouthpiece ranging from 15.7% to 29.1% ND. The percentage of the delivered medication reaching the lungs was determined to be 13.7%–18.5% ND delivered without significant differences between the experimental conditions tested. The ODAPT MV performed well compared with the RTC-26C under similar conditions (17.9% and 16.6% ND, respectively). Conclusion: The medication delivered through mechanical ventilation using the ODAPT MV adapter represents about one third the dose delivered directly through the Respimat SMI in vivo .

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.153
Threshold uncertainty score0.969

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.267
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Aerosol Medicine and Pulmonary Drug DeliverySame topicInhalation and Respiratory Drug DeliveryFrench-language works237,207