MétaCan
Menu
Back to cohort

Biomechanical design using in-vitro finite element modeling of distal femur fracture plates made from semi-rigid materials versus traditional metals for post-operative toe-touch weight-bearing

2020· article· en· W3108217901 on OpenAlex
Aaron Gee, Habiba Bougherara, Emil H. Schemitsch, Radovan Zdero

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueMedical Engineering & Physics · 2020
Typearticle
Languageen
FieldMedicine
TopicBone fractures and treatments
Canadian institutionsLondon Health Sciences CentreWestern UniversityToronto Metropolitan UniversityVictoria Hospital
FundersWestern University
KeywordsStress shieldingMaterials scienceFemurWeight-bearingFemur fractureFinite element methodStress (linguistics)Femoral shaftCortical boneElastic modulusBiomedical engineeringOrthodonticsComposite materialSurgeryStructural engineeringMedicineImplantAnatomyEngineering

Abstract

fetched live from OpenAlex

This proof-of-concept study designs distal femur fracture plates from semi-rigid materials vs. traditional metals for toe-touch weight-bearing recommended to patients immediately after surgery. The two-fold goal was to (a) reduce stress shielding (SS) by increasing cortical bone stress thereby reducing the risk of bone absorption and plate loosening, and (b) reduce delayed healing (DH) via early callus formation by optimizing axial interfragmentary motion (AIM). Finite element analysis was used to design semi-rigid plates whose elastic moduli E ensured plates permitted AIM of 0.2 - 1 mm for early callus formation. A low hip joint force of 700 N (i.e. 100% x body weight) was applied, which corresponds to a typical 140 N toe-touch foot-to-ground force (i.e. 20% x body weight) recommended to patients after surgery. Analysis was done using 2 screw materials (steel or titanium) and types (locked or non-locked). Steel and titanium plates were also analyzed. Semi-rigid plates (vs. metal plates) had lower overall femur/plate construct stiffnesses of 508 - 1482 N/mm, higher cortical bone stresses under the plate by 2.02x - 3.27x thereby reducing SS, and lower E values of 414 - 2302 MPa to permit AIM of 0.2 - 1 mm thereby reducing DH.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.570
Threshold uncertainty score0.964

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.056
GPT teacher head0.278
Teacher spread0.222 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it