MétaCan
Menu
Back to cohort
Record W3109054575 · doi:10.1002/pip.3379

Economic analysis of a novel design of microtracked concentrating photovoltaic modules

2020· article· en· W3109054575 on OpenAlexafffund
David J. Wright, Lauren Liu, Laura Parvan, Zigurts K. Majumdar, Noel C. Giebink

Bibliographic record

VenueProgress in Photovoltaics Research and Applications · 2020
Typearticle
Languageen
FieldEngineering
Topicsolar cell performance optimization
Canadian institutionsWilfrid Laurier UniversityUniversity of Ottawa
FundersUniversity of Ottawa
KeywordsPhotovoltaic systemPhotovoltaicsTariffLas vegasElectricityCost of electricity by sourceSolar irradianceBattery (electricity)IrradianceEnvironmental scienceElectricity generationEngineeringAutomotive engineeringAgricultural economicsOperations managementElectrical engineeringEconomicsMeteorologyGeographyPower (physics)

Abstract

fetched live from OpenAlex

Abstract A new design for microtracked concentrating photovoltaics (mCPVs) published by one of us in Nature Energy has the same form factor as PV. This paper analyzes the cost below which it would compete with PV in behind‐the‐meter applications for commercial electricity customers in four cities in southern United States, assuming that the only significant differences between mCPV and PV are mCPV's higher efficiency and mCPV's inability to utilize sunlight that is either diffuse or has a high angle of incidence. The analysis first optimizes PV and mCPV microgrids and then selects the battery capacity that maximizes the internal rate of return (IRR) and selects a target mCPV installed cost for which the optimal mCPV IRR matches the optimal PV IRR. The result for projects starting in 2020 is $1.2/W in Lancaster, CA and Las Vegas, cities with similar ratios of direct to total irradiance. Modesto, CA and Kansas City have target mCPV installed costs of $1.07/W and $0.94/W, respectively. The electricity tariff and battery costs impact both PV and mCPV and have a minimal effect on the mCPV cost at which the two technologies compete. mCPV occupies 33.2% less area per watt than PV reducing some components of installed cost. In 2020, target mCPV module costs are $0.33/W in Lancaster and Las Vegas, $0.25/W in Modesto, and $0.17/W in Kansas City. These target costs decline by on average 9.6% per year for projects starting 2021–2025, similar to the 9.3% rate of decline in projected PV module costs over this period.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.357
Threshold uncertainty score0.450

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.069
GPT teacher head0.326
Teacher spread0.257 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueProgress in Photovoltaics Research and ApplicationsSame topicsolar cell performance optimizationFrench-language works237,207