MétaCan
Menu
Back to cohort
Record W3109271484 · doi:10.1113/ep089074

Regional variation in the reliability of sweat rate measured via the ventilated capsule technique during passive heating

2020· article· en· W3109271484 on OpenAlexafffund
Maura M. Rutherford, Ashley P. Akerman, Sean R. Notley, Robert D. Meade, Madison D. Schmidt, Glen P. Kenny

Bibliographic record

VenueExperimental Physiology · 2020
Typearticle
Languageen
FieldMedicine
TopicThermoregulation and physiological responses
Canadian institutionsUniversity of Ottawa
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsSWEATReliability (semiconductor)CapsuleVariation (astronomy)Environmental scienceMedicineInternal medicineThermodynamicsPhysicsBiology

Abstract

fetched live from OpenAlex

Abstract The ventilated capsule technique is widely used to measure time‐dependent changes in sweating in humans. However, evaluations of its reliability (consistency) have been restricted to the forearm, despite extensive regional heterogeneity in the sweating response. Given the importance of such information for experimental design, statistical analysis and interpretation, we determined the reliability of local sweat rate at nine sites during whole‐body passive (resting) heating. On three separate occasions, a water‐perfused suit was used to increase and clamp oesophageal temperature 0.6, 1.2 and 1.8°C above baseline in 14 young men [24 (SD 5) years of age], while sweat rate was measured at the forehead, chest, abdomen, biceps, forearm, hand, quadriceps, calf and foot using ventilated capsules (3.8 cm 2 ). Absolute and relative reliability were determined via the coefficient of variation (CV) and intraclass correlation coefficient (ICC), respectively. At low heat strain (0.6°C), almost all sites had acceptable relative reliability (ICC ≥ 0.70) and moderate absolute reliability (CV < 25%). At moderate heat strain (1.2°C), only the abdomen, hand, quadriceps and foot had acceptable relative reliability, whereas the forehead, abdomen, forearm, hand and quadriceps had moderate absolute reliability. At high heat strain (1.8°C), relative reliability was acceptable at the abdomen, quadriceps, calf and foot, whereas the chest, abdomen, forearm, hand, quadriceps, calf and foot had moderate absolute reliability. Our findings indicate that the measurement site and level of heat strain impact the consistency of local sweat rate measured via the ventilated capsule technique, and we demonstrate the possible implications for research design and data interpretation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.537
Threshold uncertainty score0.218

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.299
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueExperimental PhysiologySame topicThermoregulation and physiological responsesFrench-language works237,207