MétaCan
Menu
Back to cohort
Record W3112236605 · doi:10.1109/tuffc.2020.3043326

3-D Large-Pitch Synthetic Transmit Aperture Imaging With a Reduced Number of Measurement Channels: A Feasibility Study

2020· article· en· W3112236605 on OpenAlexafffund
Ying Li, Michael C. Kolios, Yuan Xu

Bibliographic record

VenueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2020
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsToronto Metropolitan University
FundersNatural Sciences and Engineering Research Council of CanadaCanada Foundation for InnovationRyerson University
KeywordsComputer scienceAperture (computer memory)Transmission (telecommunications)AlgorithmSynthetic aperture radarGaussianPhysicsArtificial intelligenceTelecommunicationsAcoustics

Abstract

fetched live from OpenAlex

A 3-D synthetic transmit aperture ultrasound imaging system with a fully addressed array usually leads to high hardware complexity and cost since each element in the array is individually controlled. To reduce the hardware complexity, we had presented the large-pitch synthetic transmit aperture (LPSTA) ultrasound imaging for 2-D imaging using a 1-D phased array to reduce the number of measurement channels M (the product of number of transmissions, [Formula: see text], and the number of receiving channels in each transmission, [Formula: see text]). In this article, we extend this method to a 2-D matrix array for 3-D imaging. We present both numerical simulations and experimental measurements. We combined L × L adjacent elements into transmission subapertures (SAP) and K × K adjacent elements into receive SAPs in synthetic transmit aperture (STA) imaging. In the image reconstruction, we conducted the first attempt to apply and integrate Gaussian-approximated spatial response function (G-SRF) with delay and sum (DAS) to improve the image contrast, especially for the near-field targets. The imaging performance obtained from G-SRF was also evaluated numerically and compared with the previously presented frequency-domain SRF (Freq-domain SRF). The 3-D large-pitch synthetic transmit aperture (3-D-LPSTA) with G-SRF can provide a computationally efficient solution compared with the standard 3-D-STA method. With approximately 1900-fold reduction in the number of measurement channels, 3-D-LPSTA can provide image contrast comparable with the standard 3-D-STA with a full array and significantly better than using a periodically sparse array with similar complexity. In addition to reducing the system complexity, the 3-D-LPSTA achieves 700-fold reduction in computational complexity and 523-fold reduction in data storage. Finally, we evaluated and implemented the G-SRF using phantom data, which were consistent with the simulation results showing that the G-SRF can improve the image contrast. The results demonstrate that the proposed 3-D-LPSTA shows the great potential for designing an inexpensive ultrasound system to ensure the real-time 3-D clinical ultrasound imaging using large arrays. The limits of the proposed method were also discussed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.250
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlSame topicUltrasound Imaging and ElastographyFrench-language works237,207