Antithrombotic therapy after transcatheter aortic valve replacement: current perspective
Bibliographic record
Abstract
PURPOSE OF REVIEW: Transcatheter aortic valve replacement (TAVR) has expanded as a treatment option for severe aortic stenosis throughout the surgical risk spectrum. Decreasing procedural risk and inclusion of lower risk population has shifted the focus to optimization of postprocedural management and balancing the thrombotic and bleeding complications. In this review, we outline various patient and procedure related factors affecting choice of antithrombotic therapy post TAVR and provide an update of recent development in this area. RECENT FINDINGS: Multiple studies have confirmed the high incidence of both ischemic and bleeding complications in the early to midterm post-TAVR. In addition, new data has emerged for the role of high resolution computed tomography to detect decreased leaflet mobility and leaflet micro thrombi associated with implications for bioprosthetic valve dysfunction and cerebrovascular events post TAVR. Randomized clinical trials have reported increased bleeding with dual antiplatelet therapy (DAPT) and oral anticoagulation (OAC) plus antiplatelet therapy. These findings suggest that aspirin monotherapy or OAC monotherapy likely provides the appropriate balance for antithrombotic protection and risk of bleeding. SUMMARY: Majority of patients undergoing TAVR have multiple comorbidities and are at increased risk of ischemic and bleeding complications. In the absence of robust clinical evidence, there is significant variability among guideline recommendations and antithrombotic therapy post TAVR across institutions. The available evidence confirms a high rate of bleeding with more potent and prolonged antithrombotic regimens without a documented benefit for clinical endpoints. The authors favor a conservative anti thrombotic approach and suggest monotherapy with aspirin or systemic anticoagulation based upon an individual's risk of thromboembolic complications. DAPT is reserved for patients with recent stenting and OAC plus aspirin is prescribed for patients with established CAD in the post TAVR setting.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.004 | 0.010 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".