MétaCan
Menu
Back to cohort
Record W3115295780 · doi:10.1097/mop.0000000000000993

Automated control of fraction of inspired oxygen: is it time for widespread adoption?

2020· review· en· W3115295780 on OpenAlexaff
Souvik Mitra, Douglas McMillan

Bibliographic record

VenueCurrent Opinion in Pediatrics · 2020
Typereview
Languageen
FieldMedicine
TopicNeonatal Respiratory Health Research
Canadian institutionsDalhousie University
Fundersnot available
KeywordsMedicineFraction (chemistry)Chromatography

Abstract

fetched live from OpenAlex

PURPOSE OF REVIEW: Over the past two decades, numerous algorithms for automated control of the fraction of inspired oxygen (FiO2) have been developed and incorporated into contemporary neonatal ventilators and high-flow devices in an attempt to optimize supplemental oxygen therapy in preterm infants. This review explores whether current evidence is sufficient to recommend widespread adoption of automated oxygen control in neonatal care. RECENT FINDINGS: To date, 15 studies have compared automated versus manual control of FiO2 in preterm infants on respiratory support. This includes four new randomized cross-over trials published in the last 2 years. Available evidence consistently demonstrates a significant improvement in time spent within the target saturation range with automated FiO2 control. There are fewer episodes of severe hypoxemia and fewer manual FiO2 adjustments with automated oxygen control. Nursing workload may be reduced. However, no currently completed studies report on clinical outcomes, such as chronic lung disease or retinopathy of prematurity. SUMMARY: Automated oxygen control appears to be a reasonable option for FiO2 titration in preterm infants on respiratory support, if resources are available, and might substantially reduce nursing workload. Further randomized clinical trials to explore its effects on clinical outcomes are required.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.011
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.004
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.011
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0040.002
Bibliometrics0.0020.003
Science and technology studies0.0000.001
Scholarly communication0.0020.002
Open science0.0020.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.163
GPT teacher head0.479
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueCurrent Opinion in PediatricsSame topicNeonatal Respiratory Health ResearchFrench-language works237,207