MétaCan
Menu
Back to cohort
Record W3115710493 · doi:10.1111/cid.12968

Implant framework misfit: A systematic review on assessment methods and clinical complications

2020· review· en· W3115710493 on OpenAlexvenueno aff
Yu Pan, James Kit Hon Tsoi, Walter Yu Hang Lam, Ehn Pow

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2020
Typereview
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsDentistryMedicineImplantSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: The fit of implant-supported prostheses is of prime importance for the long-term success of implant therapy. PURPOSE: This systematic review aimed to evaluate recent evidence on current techniques for assessing implant-framework misfit, its associated strain/stress, and whether these misfits are related to mechanical, biological, and clinical consequences. MATERIALS AND METHODS: An electronic search for publications from January 2010 to October 2020 was performed using the Pubmed, Embase, Web of Science, and Cochrane Library databases with combined keywords on implant-framework misfit assessments and related clinical complications. Inclusion and exclusion criteria were applied. After full-text analyses, data extraction was implemented on current techniques of misfit assessment and the relationship between the misfit and the induced strain/stress. RESULTS: A total of 3 in vivo and 92 in vitro studies were selected, including 47 studies on quantifying the degree of implant-framework misfit with dimensional techniques, 24 studies measuring misfit-induced strain/stress with modeling techniques, and 24 studies using both methods. The technical details, advantages, and limitations of each technique were illustrated. The correlation between the implant-framework misfit and the induced strain/stress has been revealed in vitro, while that with the biological complications and implant/prostheses failure was weak in clinical studies. CONCLUSIONS: Dimensional and modeling techniques are available to measure the implant-framework misfit. The passivity of implant-supported fixed prostheses appeared related to the induced strain/stress, but not the clinical complications. Further studies combining three-dimensional (3D) assessments using dimensional and modeling techniques was needed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.020
metaresearch head score (Gemma)0.089
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.020
Threshold uncertainty score0.107

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0200.089
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0110.013
Bibliometrics0.0200.020
Science and technology studies0.0010.002
Scholarly communication0.0040.003
Open science0.0030.002
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.380
GPT teacher head0.658
Teacher spread0.278 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations103
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207