MétaCan
Menu
Back to cohort
Record W3118265317 · doi:10.1002/cjce.24028

Calibration of solids concentration optical fibre probes with solids‐polymer blocks

2021· article· en· W3118265317 on OpenAlexaffvenue
Jaber Shabanian, Mojtaba Mokhtari, Jamal Chaouki

Bibliographic record

VenueThe Canadian Journal of Chemical Engineering · 2021
Typearticle
Languageen
FieldEngineering
TopicElectrical and Bioimpedance Tomography
Canadian institutionsPolytechnique Montréal
Fundersnot available
KeywordsCalibrationMaterials sciencePolymerCalibration curveExtrusionPlastics extrusionSuspended solidsPolypropyleneComposite materialAnalytical Chemistry (journal)OpticsChemistryChromatographyEnvironmental science

Abstract

fetched live from OpenAlex

Abstract Owing to the determinant effects of the local distribution of solids concentration on transport phenomena, particularly in gas‐solids flows in such processing units as gas‐solid fluidized beds and pneumatic conveying lines, its accurate measurement has received considerable attention. Despite the widespread applications of optical fibre probes for the measurement of local solids concentration, these instruments may create measurement uncertainties due to their structural designs and challenges in their accurate calibrations. Several calibration methods have been proposed in the literature, while they need to be further improved. In the present study, we calibrated in‐house, fabricated, solids concentration mixed parallel optical fibre probes by two sets of solids‐polymer blocks covering solids volume fractions in the range of 0‐0.30. The uniform blocks were produced by a twin‐screw extruder and an injection moulding machine. FCC particles, 86 μm in diameter, formed the dispersed solids in the blocks, while poly styrene and poly methyl methacrylate were separately acting as the transparent medium. They helped us investigate the effects of the refractive index of the medium and the probe tip design on the calibration curve. The blind distance (zone) in front of the adopted probes was determined, at about 0.70 mm, upon measuring their reflective curves. Two glass windows with 1.00 and 1.60 mm thicknesses were separately installed at the tip of a probe to study their effects on the calibration curve. Experimental results indicated that in the absence of a glass window, the probes' voltage readings varied nonlinearly with solids concentration, the voltage readings were higher for blocks with a higher refractive index of the transparent medium, while the normalized calibration curves were similar for both sets of solids‐polymer blocks. In addition, the extent of the uniform distribution of illuminating and reflecting fibre strands at the tip of a mixed parallel optical fibre probe can change the degree of nonlinearity of its calibration curve. The application of glass windows thicker than the blind distance decreased the degree of nonlinearity of the calibration curve, yet did not completely eliminate it.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.012
Threshold uncertainty score0.318

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.164
Teacher spread0.160 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueThe Canadian Journal of Chemical EngineeringSame topicElectrical and Bioimpedance TomographyFrench-language works237,207