MétaCan
Menu
Back to cohort
Record W3118630698 · doi:10.21203/rs.2.18820/v1

Ultrasound assessment of central venous pressure: A systematic review and meta-analysis

2019· review· en· W3118630698 on OpenAlexafffund
Jean Deschamps, Jed Lipes, Andrew Weinstock, Dev Jayaraman, Lawrence Rudski, Jonathan Afilalo

Bibliographic record

Venuenot available
Typereview
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsMcGill UniversityUniversity of Alberta
FundersCanadian Institutes of Health Research
KeywordsMeta-analysisCentral venous pressureUltrasoundMedicineSystematic reviewInternal medicineMEDLINEPolitical scienceRadiologyBlood pressureLaw

Abstract

fetched live from OpenAlex

Abstract Background Ultrasound is increasingly relied upon to estimate central venous pressure (CVP) in the echocardiography lab and using point-of-care systems in the intensive care unit and the emergency department. However, there is uncertainty regarding the diagnostic accuracy of ultrasound-based parameters as reported in diverse studies.Methods A systematic review was performed by searching MEDLINE, EMBASE, and the Cochrane Database for studies evaluating ultrasound-based indicators of filling pressures in relation to catheterization-based CVP. Studies were screened for predefined inclusion criteria and rated for quality by duplicate observers. Standardized correlation coefficients for each ultrasound-based indicator were meta-analyzed using a random effects model.Results 3949 articles were screened and 64 met the criteria for inclusion. Inferior vena cava (IVC) diameter was assessed in 34 study measures and the pooled standardized correlation with invasive CVP was 0.74 (95% CI 0.63 to 0.84). IVC collapsibility was assessed in 20 study measures and the pooled standardized correlation with invasive CVP was -0.57 (95% CI -0.70 to -0.44). Tricuspid E/Ep was assessed in 6 study measures and the pooled standardized correlation with invasive CVP was 0.59 (95% CI 0.26 to 0.93). IVC parameters but not E/Ep remained correlated with CVP in mechanically ventilated patients, including cardiac surgery patients. Results were similar in studies featuring non-traditional users and cardiac specialists.Conclusions Echocardiographic IVC diameter, collapsibility, and tricuspid E/Ep ratio are significantly correlated with invasive CVP, albeit with important heterogeneity between studies. Most of these indicators are equally valid when applied in ventilated patients and by non-traditional users.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.012
metaresearch head score (Gemma)0.034
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.018
Threshold uncertainty score0.064

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0120.034
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0180.032
Bibliometrics0.0060.008
Science and technology studies0.0010.001
Scholarly communication0.0030.002
Open science0.0020.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.099
GPT teacher head0.413
Teacher spread0.313 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2019
Admission routes2
Has abstractyes

Explore more

Same topicHemodynamic Monitoring and TherapyFrench-language works237,207