MétaCan
Menu
Back to cohort
Record W3118818657 · doi:10.2967/jnumed.120.252429

Simulation of Low-Dose Protocols for Myocardial Perfusion <sup>82</sup>Rb Imaging

2021· article· en· W3118818657 on OpenAlexaff
Martin Lyngby Lassen, Yuka Otaki, Paul Kavanagh, Robert J.H. Miller, Daniel S. Berman, Piotr J. Slomka

Bibliographic record

VenueJournal of Nuclear Medicine · 2021
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsLibin Cardiovascular Institute of AlbertaUniversity of Calgary
Fundersnot available
KeywordsMedicinePerfusionMyocardial perfusion imagingCoronary artery diseaseNuclear medicineCardiac PETPerfusion scanningBlood flowFractional flow reserveCoronary arteriesCardiologyInternal medicineArteryRadiologyCoronary angiographyMyocardial infarction

Abstract

fetched live from OpenAlex

Quantification of myocardial perfusion and myocardial blood flow using 82Rb PET is increasingly used for assessment of coronary artery disease. Current guidelines suggest injections of 1,100–1,500 MBq for both stress and rest. Reducing the injected dose avoids PET system saturation in first-pass flow images and reduces radiation exposure, but the impact on myocardial perfusion quantification of static perfusion images is not fully understood. In this study, we aimed to evaluate the feasibility of performing myocardial perfusion scans using either a half-dose (HfD) or quarter-dose (QD) protocol using reconstructions from acquired full-dose (FD) scans. Methods: This study comprised 171 patients who underwent rest/stress 82Rb PET with a 3-dimensional 4-ring PET/CT scanner using a FD protocol and invasive coronary angiography within 6 mo of the PET emission scan. HfD and QD reconstructions were obtained using the prescribed percentage of events from the FD list-mode files. The total perfusion deficit was quantified for rest (rTPD), stress (sTPD), and ischemia (ITPD = sTPD − rTPD). Diagnostic accuracy for obstructive coronary artery disease, defined as at least 70% stenosis in any of the 3 major coronary arteries, was compared with area under the receiver-operating-characteristic curve (AUC). Results: Patients with a median body mass index of 28.0 (interquartile range, 23.9–31.7) were injected with doses of 1,165 ± 189 MBq of 82Rb. For sTPD, FD and HfD protocols had similar AUCs (FD, 0.807; HfD, 0.802; P = 0.108), whereas QD had a reduced AUC (0.786, P = 0.037). There was no difference in the AUC obtained for ITPD among the 3 protocols (FD, 0.831; HfD, 0.835; QD, 0.831; all P ≥ 0.805). Conclusion: HfD imaging does not affect the quantitative diagnostic accuracy of 82Rb PET on 3-dimensional PET/CT systems and could be used clinically.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.335
Teacher spread0.313 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2021
Admission routes1
Has abstractyes

Explore more