MétaCan
Menu
Back to cohort
Record W3123818726 · doi:10.14447/jnmes.v23i4.a04

Influence of Heat Disturbance on the Performance of YSZ based CO2 Sensor with Compound of Li2CO3-BaCO3-Nd2O3 as Auxiliary Sensing Electrode

2020· article· en· W3123818726 on OpenAlexvenueno aff
Guangwei Wang, Hongzhen Chen, Yuanhui Wu

Bibliographic record

VenueJournal of New Materials for Electrochemical Systems · 2020
Typearticle
Languageen
FieldEngineering
TopicGas Sensing Nanomaterials and Sensors
Canadian institutionsnot available
FundersDepartment of Education of Guizhou ProvinceGuizhou Science and Technology DepartmentNational Natural Science Foundation of China
KeywordsPotentiometric sensorElectrodeInertYttria-stabilized zirconiaMaterials sciencePotentiometric titrationInert gasElectrochemistryWater vaporWork (physics)Electrochemical gas sensorReference electrodeAnalytical Chemistry (journal)ChemistryThermodynamicsComposite materialChromatographyCubic zirconia

Abstract

fetched live from OpenAlex

Suddenly changes and fluctuations of temperature often occur in the operational environment of the CO2 electrochemical sensor. In this work, the YSZ based potentiometric CO2 sensor having Li2CO3-BaCO3-Nd2O3 compound as its auxiliary sensing material was prepared. And the effects of several types of heat disturbance on the performance of this kind of sensor ware studied. The results indicate that the sensors after heat disturbances respond similarly with the sensor as prepared, which presents rapid and correct response for the change of CO2 concentration within the experimental range of 271-576802 ppm. The sensors, with or without heat disturbance, respond well as different extents of abrupt alteration of CO2 concentration occurs, and the EMF outputs recover rapidly as the concentration of CO2 change back to the base value. At the constant concentration of CO2, the EMFs of the sensors with or without heat treatment decrease slowly as the time increases, the reason for this phenomenon might be the accumulation of inert substances on the electrode interfaces and ageing of electrodes. However, heat treatment can improve the long-term stability of the sensor to some extent. Furthermore, this type of sensor works stably with the existence of water vapor (10%), it has similar response curve in the dry and water vapor content system. After some further investigations and improvements, it might be potentially applied in the practical combustion atmosphere.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.195
Teacher spread0.186 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of New Materials for Electrochemical SystemsSame topicGas Sensing Nanomaterials and SensorsFrench-language works237,207