MétaCan
Menu
Back to cohort
Record W3124785809 · doi:10.1097/eja.0000000000001458

High flow nasal oxygen during procedural sedation for cardiac implantable electronic device procedures

2021· article· en· W3124785809 on OpenAlexaffabout
Aaron Conway, Peter Collins, Kristina Chang, Navpreet Kamboj, Ana Lopez Filici, Phoebe Pui Ying Lam, Matteo Parotto

Bibliographic record

VenueEuropean Journal of Anaesthesiology · 2021
Typearticle
Languageen
FieldMedicine
TopicAnesthesia and Sedative Agents
Canadian institutionsUniversity of TorontoUniversity Health Network
Fundersnot available
KeywordsMedicineSedationAnesthesiaNasal cannulaVentilation (architecture)Randomized controlled trialSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: High flow nasal oxygen may better support the vulnerable respiratory state of patients during procedural sedation. OBJECTIVE: The objective of this study was to investigate the effects of high flow nasal oxygen in comparison to facemask oxygen on ventilation during cardiac implantable electronic device procedures performed with procedural sedation. DESIGN: A randomised controlled trial. SETTING: The study was conducted at one academic hospital in Canada. PARTICIPANTS: Adults undergoing elective cardiac implantable electronic device procedures with sedation administered by an anaesthesia assistant, supervised by an anaesthesiologist from August 2019 to March 2020. INTERVENTIONS: Participants were randomised 1 : 1 to facemask (≥ 8 l · min-1) or high flow nasal oxygen (50 l · min-1 and a 50 : 50 oxygen to air ratio). MAIN OUTCOME MEASURES: The primary outcome was peak transcutaneous carbon dioxide. Outcomes were analysed using Bayesian statistics. RESULTS: The 129 participants who were randomised and received sedation were included. The difference in peak transcutaneous carbon dioxide was 0.0 kPa (95% CI -0.17 to 0.18). Minor adverse sedation events were 6.4 times more likely to occur in the high flow nasal oxygen group. This estimate is imprecise (95% CI 1.34 to 42.99). The odds ratio for oxygen desaturation for the high flow nasal oxygen group compared with the facemask group was 1.2 (95% CI 0.37 to 3.75). The difference in satisfaction with sedation scores between groups was 0.0 (95% CI -0.33 to 0.23). CONCLUSIONS: Ventilation, as measured by TcCO2, is highly unlikely to differ by a clinically important amount between high flow nasal oxygen at 50 l min-1 or facemask oxygen at 8 l min-1. Further research with a larger sample size would be required to determine the optimal oxygen:air ratio when using high flow nasal oxygen during cardiac implantable electronic device procedures performed with sedation. TRIAL REGISTRATION NUMBER: NCT03858257.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.737
Threshold uncertainty score0.550

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.252
Teacher spread0.238 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueEuropean Journal of AnaesthesiologySame topicAnesthesia and Sedative AgentsFrench-language works237,207