Retracted: Application of Robot Positioning for Cannulated Screw Internal Fixation in the Treatment of Femoral Neck Fracture: Retrospective Study
Why is this work in the frame?
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
No Canadian affiliation. An affiliation-only frame — the usual design — would never have seen this work. It is one of the works that make the case for inverting the frame.
Post-publication record
OpenAlex flags this work as retracted, but it carries no matching Retraction Watch record in this frame.
Abstract
BACKGROUND: Femoral neck fracture is a common type of hip fracture. Conventional surgical treatment aims at fixing the fracture site with screws and then gradually promoting bone healing. A robot-assisted orthopedic surgery system is computer technology applied to surgical treatment. OBJECTIVE: This study aimed to explore the therapeutic effect and prognostic value of percutaneous cannulated screw internal fixation using robot-assisted positioning in patients with femoral neck fractures. METHODS: From July 2018 to September 2019, 42 cases of femoral neck fracture admitted to the Second Affiliated Hospital of Luohe Medical College were randomly and averagely divided into control and study groups. The patients in the control group were treated with conventional percutaneous cannulated screw internal fixation, while the patients in the study group were treated with robot-assisted percutaneous cannulated screw fixation during surgical treatment. We compared the treatment conditions and results of the operation between the 2 groups. The Harris score was used to evaluate the treatment efficacy. The state of fracture healing was followed up and compared between the 2 groups. RESULTS: The duration of the operation was shorter, there was less fluoroscopy use, and there were fewer drilled holes in the study group than in the control group (all, P<.001). There was no statistical difference in the amount of intraoperative bleeding between the 2 groups (P=.33). The Harris score (P=.045) and number of excellent and good ratings (P=.01) were significantly higher in the study group than in the control group. The difference in the fracture healing rate between the 2 groups was not statistically significant (P=.23). The fracture healing duration of the study group was shorter than that of the control group (P=.001). CONCLUSIONS: The use of robotic positioning aids in the treatment of femoral neck fractures with percutaneous cannulated screw fixation can effectively improve the efficiency of surgery, shorten the duration of surgery, and reduce the radiation damage to patients. Meanwhile, it improves postoperative treatment and recovery rates of the patients and shortens the fracture healing time.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
The record
- Venue
- JMIR Medical Informatics
- Topic
- Hip and Femur Fractures
- Field
- Medicine
- Canadian institutions
- —
- Funders
- —
- Keywords
- MedicinePercutaneousSurgeryInternal fixationFemoral neckFluoroscopyOrthopedic surgeryBone healingFixation (population genetics)OsteoporosisInternal medicine
- Has abstract in OpenAlex
- yes