The Feasibility of a Novel Index From a Wireless Doppler Ultrasound Patch to Detect Decreasing Cardiac Output in Healthy Volunteers
Bibliographic record
Abstract
INTRODUCTION: Early hemorrhage is often missed by traditional vital signs because of physiological reserve, especially in the young and healthy. We have developed a novel, wearable, wireless Doppler ultrasound patch that tracks real-time blood velocity in the common carotid artery. MATERIALS AND METHODS: We studied eight healthy volunteers who decreased their cardiac output using a standardized Valsalva maneuver. In all eight, we simultaneously monitored the velocity time integral (VTI) of the common carotid artery (using the ultrasound patch) as well as the descending aorta (using a traditional pulsed wave duplex imaging system); the descending aortic VTI was used as a surrogate for left ventricular stroke volume (SV). Additionally, in a subset of four, we simultaneously measured SV using a noninvasive pulse contour analysis device. RESULTS: From baseline to peak effect of Valsalva, there was a statistically significant fall in descending aortic and common carotid VTI of 37% (P = 0.0005) and 23% (P < 0.0001), respectively. Both values returned to baseline on recovery. Additionally, a novel index from the carotid ultrasound patch (i.e., the heart rate divided by the carotid artery VTI) detected a 10% fall in aortic VTI with high sensitivity and specificity (100% and 100%, respectively); this novel index also accurately detected a 10% decrease in SV as measured by the noninvasive SV monitor. The mean arterial pressure, measured by the noninvasive pulse contour device, did not correctly detect the fall in SV. CONCLUSION: In summary, a novel index from a wireless Doppler ultrasound patch may be more sensitive and specific for detecting decreased cardiac output than standard vital signs in healthy volunteers.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".