MétaCan
Menu
Back to cohort
Record W3126199626 · doi:10.25259/sni_824_2020

Frame-based versus frameless stereotactic brain biopsies: A systematic review and meta-analysis

2021· review· en· W3126199626 on OpenAlexaff
Mohamad Kesserwan, Husain Shakil, Melissa Lannon, Ryan McGinn, Laura Banfield, Siddharth Nath, Mazen Alotaibi, Ekkehard Kasper, Sunjay Sharma

Bibliographic record

VenueSurgical Neurology International · 2021
Typereview
Languageen
FieldMedicine
TopicGlioma Diagnosis and Treatment
Canadian institutionsHamilton Health SciencesMcMaster University
Fundersnot available
KeywordsMedicineStereotaxyConfidence intervalStereotactic biopsyAsymptomaticMeta-analysisBrain biopsyBiopsyRadiologySurgeryInternal medicine

Abstract

fetched live from OpenAlex

Background: Stereotactic brain biopsy techniques have been a focus of rapid technological innovation. The recent advent of frameless stereotaxy has invited the question of whether it can provide the same diagnostic yield as frame-based techniques, without increasing risk of harm to patients. The goal of this meta-analysis was to compare each of these techniques in terms of yield and safety. Methods: We independently searched four databases for English studies comparing frameless and frame-based stereotactic brain biopsies. Our primary outcome was biopsy diagnostic yield. Our secondary outcomes included mortality, morbidity (e.g., symptomatic postbiopsy intracranial hemorrhage, asymptomatic postbiopsy intracranial hemorrhage, new postbiopsy neurological deficit, and postbiopsy seizure), and frequency of repeat biopsy. We calculated pooled estimates and relative risks for dichotomous outcomes using Review Manager 5.3, with corresponding 95% confidence intervals. Results: A total of 3256 stereotactic brain biopsies (2050 frame based and 1206 frameless), from 20 studies, were included in our final analysis. The results did not demonstrate any significant difference between the two stereotactic systems in terms of diagnostic yield (risk ratio [RR] 1.00, 95% confidence interval [CI] 0.99–1.02, P = 0.64, I2 = 0%). The only significant difference was the increased frequency of asymptomatic hemorrhages in the frameless group (RR 1.37, 95% CI 1.06–1.75, P = 0.01, I2 = 0%). Application of Grading of Recommendations Assessment, Development, and Evaluation to the results yielded very low quality of all outcomes. Conclusion: Based on very low-quality evidence, both frame-based and frameless stereotaxy are safe and effective for biopsy of intracranial tumors. Further study of patient preference and cost comparing analysis is required to identify if either modality should be preferred.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.013
metaresearch head score (Gemma)0.035
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.017
Threshold uncertainty score0.068

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0130.035
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0170.033
Bibliometrics0.0050.006
Science and technology studies0.0010.001
Scholarly communication0.0030.002
Open science0.0020.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.099
GPT teacher head0.398
Teacher spread0.299 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations43
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueSurgical Neurology InternationalSame topicGlioma Diagnosis and TreatmentFrench-language works237,207