MétaCan
Menu
Back to cohort
Record W3127400770 · doi:10.1002/ccd.29538

Balloon versus self‐expandable transcatheter aortic valve implantation for bicuspid aortic valve stenosis: A meta‐analysis of observational studies

2021· review· en· W3127400770 on OpenAlexaff
Michel Pompeu Sá, Matheus Simonato, Jef Van den Eynde, Luiz Rafael P. Cavalcanti, Ali Alsagheir, Aspasia Tzani, Luca Nai Fovino, Polydoros Ν. Kampaktsis, Pietro Laforgia, Arjang Ruhparwar, Alexander Weymann, Sameer Hirji, Tsuyoshi Kaneko, Gilbert H.L. Tang

Bibliographic record

VenueCatheterization and Cardiovascular Interventions · 2021
Typereview
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsMcMaster UniversityImpact
Fundersnot available
KeywordsMedicineBicuspid aortic valveCardiologyStenosisInternal medicineBalloonObservational studyBicuspid valveAortic valveAortic valve stenosisMeta-analysis

Abstract

fetched live from OpenAlex

BACKGROUND: There is a rising trend for transcatheter aortic valve implantation (TAVI) in bicuspid aortic stenosis patients. Data on the use of self-expandable (SEV) vs. balloon-expandable (BEV) valves in these patients are scarce. Therefore, we systematically compared clinical outcomes in bicuspid aortic stenosis patients treated with SEV and BEV. METHODS: Data were extracted from PubMed/MEDLINE, EMBASE, CENTRAL/CCTR, ClinicalTrials.gov, SciELO, LILACS, Google Scholar and reference lists of relevant articles. Eight studies published from 2013 to 2020 including a total of 1,080 patients (BEV: n = 620; SEV: n = 460) were selected. Primary endpoints were procedural, 30-day and 1-year mortality. Secondary endpoints were new pacemaker implantation, annular rupture, coronary obstruction, moderate-to-severe paravalvular leak, need of second valve, stroke and acute kidney injury. RESULTS: We found no statistically significant difference in mortality between patients treated with BEV vs. SEV during index procedure, at 30 days and at 1 year. BEVs showed a statistically significant higher risk of annulus rupture (2.5%) in comparison with SEV (0%) (OR 5.81 [95% CI, 3.78-8.92], p < .001). New generation BEVs were also associated with significantly less paravalvular leak when compared to new generation SEVs (OR 0.08 [95% CI, 0.02-0.35], p = .001). CONCLUSIONS: This meta-analysis of observational studies of TAVI for bicuspid valves, showed no difference in short- and mid-term TAVI mortality with BEVs and SEVs. BEVs presented a higher risk of annular rupture in comparison with SEV.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.016
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.010
Threshold uncertainty score0.042

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0080.016
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0100.025
Bibliometrics0.0030.005
Science and technology studies0.0000.000
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.218
GPT teacher head0.441
Teacher spread0.224 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations36
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueCatheterization and Cardiovascular InterventionsSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207