MétaCan
Menu
Back to cohort
Record W3129305073 · doi:10.1097/ftd.0000000000000873

Tacrolimus Measured in Capillary Volumetric Microsamples in Pediatric Patients—A Cross-Validation Study

2021· article· en· W3129305073 on OpenAlexaff
Ingvild Andrea Kindem, Anna Bjerre, Anders Åsberg, Karsten Midtvedt, Stein Bergan, Nils Tore Vethe

Bibliographic record

VenueTherapeutic Drug Monitoring · 2021
Typearticle
Languageen
FieldMedicine
TopicRenal Transplantation Outcomes and Treatments
Canadian institutionsPediatric Oncology Group
FundersNorges Forskningsråd
KeywordsVenipunctureMedicineVenous bloodTacrolimusConfidence intervalDosingMean differenceTherapeutic drug monitoringPharmacokineticsUrologyInternal medicineSurgeryTransplantation

Abstract

fetched live from OpenAlex

BACKGROUND: Therapeutic drug monitoring of tacrolimus (Tac) is mandatory in solid organ transplant (SOT) recipients. Finger-prick microsampling is more flexible and tolerable during the therapeutic drug monitoring of tacrolimus and has been shown to be applicable in adult SOT recipients. In this study, a previously validated method applying volumetric absorptive microsampling (VAMS) to measure Tac in adults was cross-validated in a pediatric population. METHODS: Patients with SOT scheduled for standard posttransplant follow-up visits were recruited. Blood samples were obtained by trained phlebotomists using standard venipuncture and capillary microsampling, before the morning dose of Tac as well as 2 and 5 hours after dosing. Tac concentrations were quantified using liquid chromatography-tandem mass spectrometry. Concordance between Tac concentrations obtained with venipuncture and VAMS was evaluated using Passing-Bablok regression, calculation of absolute and relative differences, and percentage of samples within ±20% and ±30% difference. RESULTS: A total of 39 SOT patients aged 4-18 years (22 male) were included. The median (range) predose venous blood concentration was 4.8 (2.6-13.6) mcg/L, with a difference between VAMS and venous blood samples of -0.2 ± 0.7 mcg/L. The relative mean difference was -1.3% [95% confidence interval (CI), -5.9% to 3.4%]. Ninety-two percent and 97% of the sample pairs demonstrated differences within ±20% and ±30%, respectively. Postdose (2 hours and/or 5 hours, n = 17) median concentration in venous blood was 7.9 (4.8-19.2) mcg/L. The difference between VAMS and venous blood samples was 0.1 ± 1.0 mcg/L, with a relative mean difference of -2.5% (95% confidence interval, -8.8% to 3.8%). Eighty-eight percent of the postdose sample pairs were within ±20% difference, and all were within ±30% difference. CONCLUSIONS: Tac concentrations can be accurately measured using VAMS technology in pediatric SOT recipients. This makes home-based Tac monitoring feasible in the pediatric population.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.334
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueTherapeutic Drug MonitoringSame topicRenal Transplantation Outcomes and TreatmentsFrench-language works237,207