MétaCan
Menu
Back to cohort
Record W3131974517 · doi:10.1002/nbm.4494

A strategy to prevent a temperature‐induced MRI artifact in warm liquid phantoms due to convection currents

2021· article· en· W3131974517 on OpenAlexafffund
Ryan T. Oglesby, Wilfred Lam, Greg J. Stanisz

Bibliographic record

VenueNMR in Biomedicine · 2021
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of TorontoSunnybrook Health Science Centre
FundersCanadian Institutes of Health Research
KeywordsArtifact (error)Imaging phantomBiomedical engineeringMaterials scienceConvectionNuclear magnetic resonanceSIGNAL (programming language)Convective heat transferNuclear medicineMechanicsComputer sciencePhysicsMedicineArtificial intelligence

Abstract

fetched live from OpenAlex

MRI phantom studies often fail to mimic the temperature of the human body, which can negatively impact accuracy. An artifact induced by increasing temperature in liquid phantoms was observed, presenting a significant challenge to temperature‐controlled experiments. In this study we characterize and provide a solution to eliminate this temperature‐induced MRI artifact. Low concentration (0.5–2.5 mM) agar phantoms were prepared. Utilizing a temperature‐controlled phantom holder, T1‐ and T2‐weighted structural images were acquired at 7 T along with quantitative B0, B1, T1, T2 and ADC maps at both 25 and 37°C. Additionally, computer simulations were conducted to demonstrate the fluid flow and thermal flux patterns in water to provide an insight into the origins of the artifact. Evidence from computer simulation and quantitative MRI strongly suggest the artifact was caused by heat transfer in the form of natural convection leading to structured patterns of signal loss in MR images. The artifact was present up to agar concentrations of 1.5 mM (T1 = 3068 ± 16 ms, T2 = 1052 ± 20 ms, ADC = 2.29 ± 0.36 × 10−3 mm2/s at 25°C; T1 = 3928 ± 44 ms, T2 = 1122 ± 24 ms, ADC = 2.64 ± 0.49 × 10−3 mm2/s at 37°C), above which point increased sample viscosity no longer allows for convection currents, thereby eliminating the artifact. The methodology described in this work simplifies quantitative MR acquisition of liquid phantoms at physiological temperature by suppressing convection currents with relatively small changes to intrinsic MR parameters (T1 increased by 1.4% and T2 decreased by 17% for 1.5 mM agar at 25°C).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.375
Teacher spread0.346 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueNMR in BiomedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207