MétaCan
Menu
Back to cohort
Record W3133716847 · doi:10.1111/bcp.14802

Comparison of the EXtracorporeal TReatments In Poisoning (EXTRIP) and Paris criteria for neurotoxicity in lithium poisoned patients

2021· article· en· W3133716847 on OpenAlexaff
Philip DiSalvo, Emma Furlano, Mark K. Su, Sophie Gosselin, Robert S. Hoffman

Bibliographic record

VenueBritish Journal of Clinical Pharmacology · 2021
Typearticle
Languageen
FieldMedicine
TopicPoisoning and overdose treatments
Canadian institutionsMcGill UniversityCentre intégré de santé et de services sociaux de Chaudière-AppalachesCentre Intégré de Santé et de Services Sociaux des Laurentides
Fundersnot available
KeywordsMedicineHemodialysisConfidence intervalLithium (medication)ExtracorporealOdds ratioRetrospective cohort studyInternal medicineSurgeryPediatrics

Abstract

fetched live from OpenAlex

AIMS: Two guidelines for haemodialysis in lithium poisoning, one from the Extracorporeal TReatments in Poisoning (EXTRIP) workgroup and a single centre retrospective one (Paris) differ. We compared outcomes in lithium poisoning based on these criteria with a primary outcome of worsening neurological symptoms in patients for whom EXTRIP and Paris criteria were discordant. METHODS: Poison centre data were queried for lithium poisoned patients for whom haemodialysis was either recommended or performed. Patients were categorized according to EXTRIP and Paris criteria and excluded if the peak lithium concentration was <1.2 mmol/L or if neurological follow-up was unavailable. Comparative analyses were only performed when both criteria could be assessed. RESULTS: In total, 219 patients were analysed. Paris criteria were met in 70 and EXTRIP criteria in 178. Forty two patients were excluded because Paris criteria could not be evaluated. When Paris and EXTRIP both supported haemodialysis, 50/57 (88%) of patients who received haemodialysis improved, as did all 3 who did not receive haemodialysis. When Paris and EXTRIP did not support haemodialysis, all nondialysed patients did well. Among the 86 patients for whom EXTRIP supported haemodialysis but Paris did not, 4/19 (21%) patients not dialysed deteriorated (P = .02; odds ratio = 8.7, 95% confidence interval = 1.5-51.8), 1 of whom died. All 8 patients for whom Paris criteria supported haemodialysis but EXTRIP did not were dialysed and improved. CONCLUSIONS: When the EXTRIP and Paris criteria are discordant, EXTRIP criteria outperforms the Paris criteria at identifying potentially ill patients who might benefit from haemodialysis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.097
GPT teacher head0.485
Teacher spread0.388 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueBritish Journal of Clinical PharmacologySame topicPoisoning and overdose treatmentsFrench-language works237,207