MétaCan
Menu
Back to cohort
Record W3135419369 · doi:10.1093/jcag/gwab002.129

A131 POINT OF CARE ULTRASOUND CHANGES THE NEEDLE INSERTION LOCATION FROM AN ANATOMICALLY LANDMARKED SITE DURING BEDSIDE PARACENTESIS.

2021· article· en· W3135419369 on OpenAlexaff
David M. Rodrigues, Arjun Kundra, Lawrence Hookey, Steven J. Montague

Bibliographic record

VenueJournal of the Canadian Association of Gastroenterology · 2021
Typearticle
Languageen
FieldMedicine
TopicUltrasound in Clinical Applications
Canadian institutionsQueen's UniversityUniversity of Toronto
Fundersnot available
KeywordsMedicineParacentesisThoracentesisCirrhosisAscitesUltrasoundPoint of care ultrasoundSurgeryRadiologyInternal medicine

Abstract

fetched live from OpenAlex

Abstract Background Paracentesis is a bedside procedure to obtain ascitic fluid from the peritoneum. It is traditionally performed using anatomic landmarking and percussion to ascertain a safe drainage site. The serious complication rate has been reported as less than 2%. Point-of-care ultrasound (POCUS) has been adopted into education and clinical use and has been shown to improve the safety of certain procedures such as central line insertion and thoracentesis. However, the evidence supporting its use is limited. Aims We aimed to assess if POCUS would yield a user-preferred site for needle insertion compared to conventional landmarking, defined as a >5cm change in location. Methods Adult patients under the care of gastroenterology or general internal medicine at Kingston Health Sciences Centre undergoing paracentesis were consecutively enrolled between January and September of 2020. Physicians performing the procedure were enrolled based on availability. An anatomic site was selected 4cm superiorly and 2-4cm medially to the anterior superior ileac spine and confirmed with dullness to percussion. POCUS was then employed to determine if there was an alternative user-preferred site. Patient and operator demographic data and procedure-related information were collected. Results A total of 30 individual patients and 24 operators were enrolled, comprising 45 unique procedure combinations. Operators were primarily in their PGY 1 and 2 years of training (33% and 31% respectively). Per procedure, patients mean age was 61, and most of the ascites was due to cirrhosis (84%) predominantly due to EtOH (47%) and NAFLD (34%). As per indication, 29% of procedures were for diagnostic purposes alone. In total, users primarily preferred the POCUS site which resulted in a change in needle insertion site >5cm from the anatomic site in 69% of cases. The average depth of fluid was greater at the POCUS site vs. the anatomic site (5.4cm+/-2.8 vs 3.0cm+/-2.5, p<0.005). On average, POCUS deflected the needle insertion site superiorly and laterally to the anatomic site. Operators listed that per procedure the POCUS site was chosen to avoid adjacent organs (38%), optimize fluid pocket (61%) and due to abdominal wall issues (primarily issues with pannus; 11.5%). Importantly 6 cases were aborted due to a lack of an appropriate fluid pocket, despite clinical and/or prior radiographic evidence of ascites. Conclusions Overall, POCUS changes the needle insertion site from the conventional anatomic site for most procedures, due to user-perceived safety concerns. POCUS also prevented an attempt at paracentesis in 6 cases that were deemed unsafe. Therefore, POCUS plays an important role in bedside paracentesis. This research supports the use of POCUS in paracentesis and argues for continued training with POCUS throughout medical school and residency. Funding Agencies None

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.258
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of the Canadian Association of GastroenterologySame topicUltrasound in Clinical ApplicationsFrench-language works237,207