MétaCan
Menu
Back to cohort
Record W3137096449 · doi:10.1186/s12968-021-00719-2

Usefulness of TI-scout images in the assessment of late gadolinium enhancement in children

2021· article· en· W3137096449 on OpenAlexaff
Badr Bannan, Julien Aguet, Aswathy Vaikom House, Navjot Gill, Vivian P. Tassos, Afsaneh Amirabadi, Mike Seed, Christopher Z. Lam, Shi‐Joon Yoo

Bibliographic record

VenueJournal of Cardiovascular Magnetic Resonance · 2021
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsSickKids FoundationHospital for Sick ChildrenUniversity of Toronto
Fundersnot available
KeywordsMedicineGold standard (test)AngiologyMagnetic resonance imagingDiagnostic accuracyRadiologyNuclear medicineInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Cardiovascular magnetic resonance (CMR) late gadolinium enhancement (LGE) requires identification of the normal myocardial nulling time using inversion time (TI)-scout imaging sequence. Although TI-scout images are not primarily used for myocardial assessment, they provide information regarding different signal recovery patterns of normal and abnormal myocardium facilitating identification of LGE in instances where standard LGE images alone are not diagnostic. We aimed to assess the diagnostic performance of TI-scout as compared to that of standard LGE images. METHODS: CMR studies with LGE imaging in 519 patients (345 males, 1-17 years) were reviewed to assess the diagnostic performance of LGE imaging in terms of the location of LGE and the pathologic entities. The diagnostic performance of the TI-scout and standard LGE imaging was classified into four categories: (1) equally diagnostic, (2) TI-scout superior to standard LGE, (3) standard LGE superior to TI-scout, and (4) complementary, by the consensus of the two observers. RESULTS: The study cohort consisted of 440 patients with negative LGE and 79 with evidence for LGE. For a negative diagnosis of LGE, TI-scout and standard LGE images were equally diagnostic in 75% of the cases and were complementary in 12%. For patients with LGE, TI-scout images were superior to standard LGE images in 52% of the cases and were complementary in 19%. The diagnostic performance of TI-scout images was superior to that of standard LGE images in all locations. TI-scout images were superior to standard LGE images in 11 of 12 (92%) cases with LGE involving the papillary muscles, in 7 /12 (58%) cases with subendocardial LGE, and in 4/7 (57%) cases with transmural LGE. TI-scout images were particularly useful assessing the presence and extent of LGE in hypertrophic cardiomyopathy (HCM). TI-scout was superior to standard LGE in 6/10 (60%) and was complementary in 3/10 (30%) of the positive cases with HCM. CONCLUSIONS: TI-scout images enhance the diagnostic performance of LGE imaging in children.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.016
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.016
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.271
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cardiovascular Magnetic ResonanceSame topicCardiac Imaging and DiagnosticsFrench-language works237,207