Effectiveness and Renal Safety of Tenofovir Alafenamide Fumarate among Chronic Hepatitis B Patients: Real‐World Study
Bibliographic record
Abstract
Abstract Tenofovir alafenamide fumarate (TAF) has high plasma stability resulting in fewer renal adverse events compared to tenofovir disoproxil fumarate (TDF) in chronic hepatitis B (CHB) patients. We aimed to study the effectiveness and renal safety of TAF in a real‐world setting, in patients with or without compromised kidney function. CHB patients (Nucleos(t)ide Analogue [NA]‐naïve or experienced) who received TAF >1 year from 11 academic institutions as part of the Canadian Hepatitis B Network (CanHepB) were included. Kidney function was measured by estimated glomerular filtration rate (eGFR) as per Cockcroft‐Gault. Patients were followed for up to 160 weeks. Of 176 patients receiving TAF, 143 switched from NA (88% TDF), and 33(19%) were NA naïve. Majority of NA‐naïve patients (75%) achieved undetectable HBV DNA after one year of TAF treatment. Majority of patients with eGFR <60 mL/min who had renal deterioration during TDF (76%) reversed to eGFR increase after one year of TAF ( p =0.009). Among patients with stage 2 chronic kidney disease (CKD) (eGFR 60–89), the estimated eGFR decline during TDF was halted after switching to TAF ( p =0.09). NA‐experienced patients with abnormal ALT before TAF showed a significant decline after switching to TAF: −0.005 [−0.006 – −0.004] log 10 ULN U/L/month, p <0.001). In CHB patients, TAF was safe, well‐tolerated and effective in this real‐world cohort. Switching to TAF led to improved kidney function, particularly in those with stage 2 CKD, which suggests that the indication for TAF in the guidelines could be extended to patients with an eGFR higher than 60 mL/min.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".