MétaCan
Menu
Back to cohort
Record W3142168229 · doi:10.1088/1361-6560/abf38a

Post-administration dosimetry in yttrium-90 radioembolization through micro-CT imaging of radiopaque microspheres in a porcine renal model

2021· article· en· W3142168229 on OpenAlexaff
Éric Henry, Matthew Strugari, George Mawko, Kimberly Brewer, Robert J. Abraham, S. Cheenu Kappadath, Alasdair Syme

Bibliographic record

VenuePhysics in Medicine and Biology · 2021
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsNova Scotia Health AuthorityDalhousie University
Fundersnot available
KeywordsVoxelDosimetryNuclear medicineMaterials scienceMonte Carlo methodBiomedical engineeringMedicineRadiologyMathematics

Abstract

fetched live from OpenAlex

Abstract The purpose of this study is to perform post-administration dosimetry in yttrium-90 radioembolization through micro-CT imaging of radiopaque microsphere distributions in a porcine renal model and explore the impact of spatial resolution of an imaging system on the extraction of specific dose metrics. Following the administration of radiopaque microspheres to the kidney of a hybrid farm pig, the kidney was explanted and imaged with micro-CT. To produce an activity distribution, 400 MBq of yttrium-90 activity was distributed throughout segmented voxels of the embolized vasculature based on an established linear relationship between microsphere concentration and CT voxel value. This distribution was down-sampled to coarser isotropic grids ranging in voxel size from 2.5 to 15 mm to emulate nominal resolutions comparable to those found in yttrium-90 PET and Bremsstrahlung SPECT imaging. Dose distributions were calculated through the convolution of activity distributions with dose-voxel kernels generated using the GATE Monte Carlo toolkit. Contours were computed to represent normal tissue and target volumes. Dose-volume histograms, dose metrics, and dose profiles were compared to a ground truth dose distribution computed with GATE. The mean dose to the target for all studied voxel sizes was found to be within 5.7% of the ground truth mean dose. D 70 was shown to be strongly correlated with image voxel size of the dose distribution ( r 2 = 0.90). D 70 is cited in the literature as an important dose metric and its dependence on voxel size suggests higher resolution dose distributions may provide new perspectives on dose-response relationships in yttrium-90 radioembolization. This study demonstrates that dose distributions with large voxels incorrectly homogenize the dose by attributing escalated doses to normal tissues and reduced doses in high-dose target regions. High-resolution micro-CT imaging of radiopaque microsphere distributions can provide increased confidence in characterizing the absorbed dose heterogeneity in yttrium-90 radioembolization.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.103
GPT teacher head0.406
Teacher spread0.303 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2021
Admission routes1
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207