MétaCan
Menu
Back to cohort
Record W3157409135 · doi:10.12659/ajcr.931058

It’s a Trap: A Case of Strangulated Coronary Guidewire and Longitudinal Stent Deformation in the Right Coronary Artery

2021· article· en· W3157409135 on OpenAlexaboutno aff
Adeel Ur Rehman, Jahanzeb Malik, Imran H. Iftikhar, Asim Javed, Anjum Jalal, Khawar Naeem Satti

Bibliographic record

VenueAmerican Journal of Case Reports · 2021
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsnot available
Fundersnot available
KeywordsPercutaneous coronary interventionMedicineArteriotomyStentRight coronary arteryConventional PCICardiologyCatheterCoronary stentArterySurgeryInternal medicineRadiologyMyocardial infarctionRestenosisCoronary angiography

Abstract

fetched live from OpenAlex

BACKGROUND Strangulation of the coronary guidewire is an infrequent complication of percutaneous coronary intervention (PCI), and it can lead to disastrous outcomes of stent thrombosis, vessel occlusion, and vessel damage. CASE REPORT Early-generation stents were made from stainless steel and had a bulky design as compared to cobalt-chromium or platinum chromium alloys, which have superior trackability at the cost of a thin core and low-strength struts, resulting in increased incidence of longitudinal stent deformation. We present a case of a 62-year-old active smoker with effort angina of Canadian Cardiovascular Society (CCS) class III. His coronary angiogram revealed a totally occluded right coronary artery (RCA). After placing 2 coronary guidewires (Run-through and Balanced middle-weight), Xience Xpedition (3.25×48 mm) and Promus Element (2.75×32 mm) were deployed through the whole length of the RCA. While placing the distal stent, the guidewire securing the posterior left ventricular (PLV) was trapped between 2 stents and all attempted maneuvers were unsuccessful in retrieving the wire. The stents sustained longitudinal deformation by the guide catheter, and subsequent arteriotomy for stent and wire retrieval and coronary artery bypass graft surgery were (CABG) performed. CONCLUSIONS Despite the remarkable safety profiles of the percutaneous equipment, complications still occur even with experienced operators. Calcified and tortuous vessels are primarily at risk for wire strangulation between stents or side-branches, and better deliverability of newer drug-eluting stents (DES) comes at the cost of reduced longitudinal strength.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: Case report
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.004
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.002
Science and technology studies0.0030.002
Scholarly communication0.0020.002
Open science0.0020.002
Research integrity0.0070.005
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.297
Teacher spread0.278 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueAmerican Journal of Case ReportsSame topicCoronary Interventions and DiagnosticsFrench-language works237,207